Electrical - Ventrac 4500Y Operator's Manual

Hide thumbs Also See for 4500Y:
Table of Contents

Advertisement

Engine (Continued)
Symptom:
Oil light comes on when running.
Engine emits white smoke.
Excessive fuel consumption.
Engine uses excessive oil.

Electrical

Anytime there is an electrical issue, first check to ensure the LED light for the Power input (bottom right
corner) of the TCM is turned on when the key switch is in the Off position. If the light is not on:
a. Check the battery disconnect switch to ensure it is turned on.
b. If the battery disconnect switch was already turned on, the TCM may be in 'Sleep' mode. Turn the
battery disconnect switch off for 10 seconds and then back on to 'Wake' the TCM.
c. Check the 15 amp fuse in slot #10 of the front fuse panel. Replace this fuse, if necessary.
Next, turn the key switch to the On position and check to see if any of the other lights turn on. If no other
lights turn on, check the 5 amp fuse in slot #8 of the front fuse panel. If any other lights turn on, you can
start troubleshooting the rest of the TCM functions.
Battery does not charge.
Lights do not activate.
Glow plugs do not activate.
TROUBLESHOOTING
Symptom:
Troubleshooting - 76
Possible Cause:
Low oil level.
Faulty oil sender.
Faulty or plugged oil pump.
Low engine temperature.
Faulty head gasket.
Water in combustion chamber.
Plugged or restricted air filters or hose.
Dirty or faulty fuel injectors.
Check for leaks.
Incorrect oil viscosity.
Plugged or restricted air filters and or hose.
Worn rings or cylinder walls.
Worn or faulty valves.
Possible Cause:
Loose or corroded connections.
Broken or loose wire in charge system.
Blown fuse or fuse link in charge system.
Defective battery.
Loose alternator belt.
Defective regulator.
Defective alternator.
Blown fuse.
Blown light bulb.
Broken wire.
Defective light switch.
Blown fuse.
Broken wire.
Faulty glow plugs.

Hide quick links: