Diagnostic Codes For Status Led; Fault Code History; Internal Lighting System - Napoleon 9700 SERIES Installation And Operating Instructions Manual

Two stage high efficiency (condensing) forced air gas furnace
Table of Contents

Advertisement

19.8 DIAGNOSTIC CODES FOR STATUS LED

STATUS
LEDs
LED OFF
LED ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
A yellow LED is provided to indicate high heat state
LED Off
LED On
LED Flashing High heat demand, high pressure switch not closed

19.9 FAULT CODE HISTORY

The control stores the last 5 fault codes in memory. When the push button switch is pressed, the
control will fl ash the stored fault codes when the switch is released. The most recent fault code is
fl ashed fi rst, the oldest last.
Fault history may be cleared by holding the push button switch for more than 5 seconds.
19.10

INTERNAL LIGHTING SYSTEM

The 9700 Series is equipped with internal LED service lights. One is located in the upper vestibule
area and the other is located in the lower blower compartment. These lights are only activated when
the bottom door is removed and the door switch is deactivated. The purpose of the interior lighting is
to ease servicing the unit.
FAULT CONDITION
No Power to control or control hardware fault detected
Normal Operation
High limit switch open
Pressure switch open with exhauster on
Pressure switch closed with exhauster off
Lockout due to too many failed ignition attempts (1 hour lockout)
L1/Neutral Polarity problem
Too many limit trips within one call for heat
Pressure switch cycle lockout
Lockout due to too many fl ame dropouts
Not used
Flame present with gas off
No demand for high heat
High heat demand, operating normally
55
W415-1064 / 11.11.11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents