FIGURE 19
A ½" PVC coupling or bushing will fi t snug over the ½" rubber hose. A ¾" CPVC coupling or bushing will fi t
snug over the 5/8" rubber hose. This method ensures a water tight seal and also allows the condensate trap to
be easily removed for service.
FIGURE 21
If extra security is desired, it is recommended to secure a strip of strapping around the drain. Utilize the
existing condensate drain screws to secure the strapping.
IMPORTANT:
IF AN AIR CONDITIONING EVAPORATOR COIL DRAIN IS TO SHARE THE FURNACE DRAIN
LINE, IT SHOULD BE CONNECTED WITH A TEE FITTING DOWNSTREAM FROM THE
TRAP. DO NOT CONNECT THE EVAPORATOR COIL CONDENSATE DRAIN UPSTREAM OF
THE FURNACE DRAIN TRAP ASSEMBLY.

11.2 CONDENSATE NEUTRALIZERS

Some local codes may require the use of a condensate neutralizer. If the furnace condensate is to be routed
to a septic system, it may be advisable to use a condensate
neutralizer.
When condensate neutralizers are used, it is advisable to install
it with an overfl ow bypass tube.
FIGURE 20
FIGURE 22