Lincoln Electric COMMANDER 400 SVM133-B Service Manual page 44

Lincoln electric welder user manual
Table of Contents

Advertisement

D-8
FREQUENCY
MAINTENANCE REQUIRED
Daily or Before
• Fill fuel tank.
Starting Engine
• Check oil level.
• Check air cleaner for dirty, loose, or damaged parts. Replace if necessary.
• Check air intake and cooling areas, clean as necessary.
1
First 50 Hours
• Change engine oil.
and Every 250
• Change oil filter.
Hours Thereafter • Change fuel filter.
• Check fan belt.
Every 50 Hours
• Check fuel lines and clamps.
Every 100 Hours
• Check battery electrolyte level and connections.
• Clean air filter.
Refer to your Deutz engine operation manual for periodic maintenance at 100 hours and beyond.
1
125 Hours for severe conditions.
MAINTENANCE
TABLE D.1
DEUTZ ENGINE MAINTENANCE SCHEDULE
COMMANDER 400
D-8