A-6
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.1 for the location of the 120 and 240 volt
receptacles, weld output terminals, and ground stud.

WELDING CABLE CONNECTIONS

CABLE INSTALLATION AND CABLE SIZES
With the engine off, route the electrode and work
cables through the strain relief bracket on the base and
connect to the terminals located on the fuel tank mount-
ing rail. (See size recommendations below.) For posi-
tive polarity, connect the electrode cable to the terminal
marked Positive (+). For Negative polarity, connect the
electrode cable to the Negative (-) terminal. These
connections should be checked periodically and tight-
ened if necessary.
120 V OLT
RE CEP TACL ES
TABLE A.1 - RECOMMENDED COPPER WELDING CABLE SIZE AND LENGTH
TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES
Amps
250
400
INSTALLATION
FIGURE A.1 - COMMANDER 400 OUTPUT CONNECTIONS
FUEL
TEMP
+
240 VO LT REC E PTAC LE
WEL D O UTP UT TER MINALS
(EL ECTRO DE + & C C W OR K - )
Duty Cycle
100%
100%
COMMANDER 400
CAUTION
• Loose connections will cause the output terminals to
overheat. The terminals may eventually melt.
• Do not cross the welding cables at the output terminal
connection. Keep the cables isolated and separate
from one another.
When welding at a considerable distance from the
welder, be sure you use ample size welding cables.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
Lincoln Electric offers a welding accessory kit with the
properly
specified
welding
Accessories section of this manual for more
information.
OIL
PRESS
AMPS
0 0 0 0 0
0
H O U R S
CV WO RK -
WELD OU TPU T
-
TER MIN AL
-
GR OU N D S TUD
Cable sizes for combined length of
electrode plus work cable
Up to 200 ft.
1 AWG
3/0 AWG
A-6
cables.
See
the
200 to 250 ft.
1/0 AWG
4/0 AWG