NORMAL SOLENOID PULL & HOLD COIL WAVEFORMS
2 V
TROUBLESHOOTING & REPAIR
100 ms
100 ms
The scope pictures above are typical
waveforms seen directly across the
pull and hold terminals on both the
Idle and Shutdown solenoids when
they are operating normally.
Note: Voltages across the shutdown
solenoid coils may be slightly lower
than these waveforms since the
engine alternator may not be running.
SCOPE SETTINGS
Volts/Div.......................2V/Div.
Horizontal ..............100ms/Div.
Coupling.............................DC
Trigger.........................Internal