Lincoln Electric CLASSIC I SVM134-A Service Manual page 59

Lincoln electric welder user manual
Table of Contents

Advertisement

F-15
EXITER
COVER
4. Turn off the engine. Using the 3/8" nut driver,
remove the exciter cover. See Figure F.2.
MOVING PARTS can injure.
• Keep hands, hair, clothing and tools away
from V-belts, gears, fans, and all other moving
parts when starting, operating, or repairing
equipment.
• If fan guards are missing from a machine,
obtain
Distributor.
greatest care when working near moving
parts.
TROUBLESHOOTING & REPAIR
DC EXCITER TEST (continued)
FIGURE F.2 – EXCITER COVER REMOVAL
WARNING
• Remove guards only when
necessary to perform service,
and replace them when the
service requiring their removal
is complete.
replacements
from
a
(See Parts List.)
Always use
CLASSIC I
CHECK VOLTAGE
AT BRUSH
HOLDERS HERE
(RIGHT SIDE IS +)
5. Start the engine. Using the volt/ohmmeter,
carefully check the DC voltage at the brush
holders.
brush holder is positive polarity. Normal DC
voltage is 125 - 135VDC with the engine at
the high idle speed of 1600 RPM.
6. If the DC voltage is normal at the brush hold-
ers, the DC exciter armature and shunt coils
are OK.
a. If the voltage is low or not present, pro-
ceed with the shunt coil and series coil
resistance tests.
b. If the correct DC voltage is present at the
brush holders but not at the 120VDC
receptacle, the series coil or associated
leads may be faulty.
Diagram. Proceed with the shunt coil and
Lincoln
series coil resistance tests.
WARRANTY
+
See Figure F.2. The right side
See the Wiring
F-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic i

Table of Contents