08H : Communication Loop Detection - Adleepower AP2G3-137 Instruction Manual

General-purpose inverter
Hide thumbs Also See for AP2G3-137:
Table of Contents

Advertisement

Computer command message
CD31 content '0'
D6
CD31 content '1'
D7 LRC HI
D8 LRC LO
END HI
END LO

(3) 08H : Communication loop detection

Computer command message
D1 : Communication address
D2 : Function code
D3 : Data 1
D4 : Data 2
D5 : Data 3
D6 : Data 4
D7 : CRCL
D8 : CRCH
AC drive response message
D1 : Communication address
D2 : Function code
D3 : Data 1
D4 : Data 2
D5 : Data 3
D6 : Data 4
D7 : CRCL
D8 : CRCH
AC drive response messages need to be same as command message when
do communication loop detection.
30
CD31 content '0'
D6
CD31 content '1'
31
LRC HI
D7 LRC HI
LRC LO
D8 LRC LO
0D
END HI
0A
END LO
(0~FFh)
(08h)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(08h)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
64
AC drive response message
30
31
LRC HI
LRC LO
0D
0A