Operation Signal
Terminal CF1
Terminal CF2
Output frequency
Speed 1

Acceleration time 2

CD25
CD42 or CD43 setting FT1 or FT2=3, then CD25 or CD26 can be
setted.

Deceleration time 2

CD26
F
(HZ)
Acceleration
time 2
2CH=ON
Acceleration
time 1
2CH=OFF
To operate inverter with 2CH function, check to see CD42 or CD43=3.
2CH command inputs from FT1 or FT2 terminal.
ON
ON
ON
ON
Speed 2
Speed 4
Speed 3
Setting Range
Default Value
Setting Range
Default Value
Deceleration time 1
2CH=OFF
Deceleration time 2
2CH=ON
Time(Sec)
Terminal
SPEED
SPEED - 1 OFF OFF
SPEED - 2 ON
Speed 1
SPEED - 3 OFF ON
SPEED - 4 ON
Acceleration time 1
Deceleration time 1
Acceleration time 2
Deceleration time 2
35
order
CF1 CF2
OFF
ON
0.1 ~ 6000.0SEC
10.0SEC
0.1 ~ 6000.0SEC
10.0SEC
Description
2CH
OFF
ON