06H: Write Parameter Setting Into Ac Drive - Adleepower AP2G3-137 Instruction Manual

General-purpose inverter
Hide thumbs Also See for AP2G3-137:
Table of Contents

Advertisement

(2) 06H : Write parameter setting into AC drive
Computer command message
D1 : Communication address
D2 : Function code
D3 : Parameter number (H)
D4 : Parameter number (L)
D5 : Content of data (H)
D6 : Content of data (L)
D7 : CRCL
D8 : CRCH
AC drive response message
D1 : Communication address
D2 : Function code
D3 : Parameter number (H)
D4 : Parameter number (L)
D5 : Content of data (H)
D6 : Content of data (L)
D7 : CRCL
D8 : CRCH
Computer write CD00 content (60.00HZ) to inverter address=52
1. RTU
Computer command message
D1
D2
34H
06H
AC drive response message
D1
D2
34H
06H
D3
D4
D5
00H
00H
17H
D3
D4
D5
00H
00H
17H
(00~FFh)
(06h)
(00h)
(0~4Eh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
(01~FFh)
(06h)
(00h)
(0~4Eh)
(0~FFh)
(0~FFh)
(0~FFh)
(0~FFh)
D6
D7
D8
70H
CRCL
CRCH
D6
D7
D8
70H
CRCL
CRCH
60