The CRX-500 Series Control Receivers with Option B1 or B2 are installed the
same as outlined in Section 2 with the following exceptions.
Exceptions:
1. RS-422 Communication Cable is not required as described in paragraph
2.6.1. RG-59 Coaxial Cable (P/N 849518-0054) with BNC connectors on
both ends is required from each CRX-500 Series Unit to the UCT-100 Data
Transmitter. RG-59 Coaxial Cable is for runs less than 800 feet.
2. The RS-422 Communication Connections described in paragraph 2.7.1 are
not done. The RS-422 control data is transmitted over the coaxial cable.
Perform the following procedure to connect the video coaxial cables. Refer to
Figure A-2.
1.
Connect the video from the camera to the Video Input on the CRX-500
Series Unit using RG-59 cable with BNC connectors on both ends.
If the CRX-502 or CRX-520 units are installed, make sure
the camera and the pan and tilt unit are connected to the
same board.