Selectable Auto/Manual Iris; Auxiliary Functions - Ultrak CRX-501 Installation And Operation Manual

Control receiver
Table of Contents

Advertisement

2.7.5.3
CONTROL RECEIVER
Terminal 5, LENS -
Terminal 4, IRIS
Terminal 6, LENS+
Terminal 7, LENS OUT "Common" side of the lens ALC output
2.7.6

Auxiliary Functions

All models of receivers have two contact outputs for controlling auxiliary
devices. The contact outputs are latched contacts that can be configured
as normally open or normally closed.

Selectable Auto/Manual Iris

To be able to select between auto and manual iris,
Option C must be installed in the control receiver and
the lens must be modified to use this option. Since
each lens is configured differently, you must consult
with the factory before using this option.
The lens ALC output that normally is connected
internally to the lens iris motor must be disconnected.
Then both the ALC output and the iris motor input must
be brought out to the control receiver board. This
includes both sides of the ALC outputs and the motor
inputs.
TB1
"Common" side of the lens iris motor
"Drive" side of the lens iris motor
"Drive side of the lens ALC output
2-27
SELECTABLE AUTO/MANUAL IRIS
LENS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crx-502Crx-510Crx-520