Iris Drive Voltage; Cabling Requirements; Rs422 Communication Cable; Power Input, Pan And Tilt Control, Lens Control, And Camera Power Cable - Ultrak CRX-501 Installation And Operation Manual

Control receiver
Table of Contents

Advertisement

2.5.7

Iris Drive Voltage.

The iris drive voltage on each board is a factory setting that should not be
changed.
Mother Board
Jumper W7
Jumper W6
2.6

CABLING REQUIREMENTS

2.6.1

RS422 Communication Cable.

Diamond Electronics recommends using 24-gauge, UL2919, twisted-pair
shielded cable, Carol CO841 or equivalent (Diamond Electronics part
number 849518-0334) to/from terminal strip TB1 for RS-422 control data.
2.6.2
Power Input, Pan and Tilt Control, Lens Control, and Camera Power
Cable.
The input power, pan/tilt functions, camera power, lens functions, and
auxiliary functions
specifications to determine cabling requirements.
Input Power
120/220 Vac ±10%, 50/60 Hz, 1.5 amps (max.)
Output Power
Pan/Tilt - 120/220/24 Vac, 1 amps (max.)
Camera - 24 Vac, 12 Vdc, 0.5 Amp (max.)
Factory Setting
Out
Pos. 1 & 2
require
site-specific cable.
2-15
Expansion Board
Jumper W6
Jumper W7
Out
Pos. 1 & 2
Use
the
following

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crx-502Crx-510Crx-520