Heat & Glo COSMO-I30AU Owner's Manual page 33

Hide thumbs Also See for COSMO-I30AU:
Table of Contents

Advertisement

NOTE: Any 3 in. (76 mm) section
of fl ex pipe must be enclosed to
existing fi replace fl ue in double
lined flue to comply with
AS2918-2001 and the building
code of Australia.
3-3/8 in.
(85 mm) Ø
FLEX FLUE
DOUGBLE SPIGOT STARTER
PLATE, FIXED TO HEBEL
TO ACCOMODATE 225 AND
275 Ø FLUES
HEBEL BLOCKS
600 X 200 X 75
Figure 8.16
A
B
C
D
SLP-TVHW
Must adhere to pipe clearances.
SLP 170 Ø
Colinear to Coaxial Adapter
LINK ADAPTER
225 & 275 Ø GALVANIZED FLUE
MINIMUM 1/4 in. (6 mm)
NON-COMBUSTIBLE
BASE (UNDER UNIT)
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. V • 6/14
Clearance to non-combustible back
Clearance from non-combustible back
to combustible material
Clearance to non-combustible header
Clearance to non-combustible top
MINIMUM TOTAL
FLUE RUN 10 ft. (3 m)
MAXIMUM TOTAL
FLUE RUN 51 ft. (15.5 m)
MINIMUM FLEX FLUE
RUN TOP OF BOX
SPIGOT TO LINK
ADAPTER 35-7/16 in.
(900 MM)
Seal connection points for duct-
ing.
NOTE: Tape all SLP pipe connec-
tions with aluminum foil tape rated
to a minimum of 300° F (149° C).
19 in. (482 mm)
4 in. (101 mm)
26 in. (660 mm)
40 in. (1016 mm)
33