E. Installing Adaptor and Termination Cap
For installation of termination cap see minimum vent
heights for various pitched roofs (see Figure 8.5).
To install adaptor see Figure 8.7.
510 mm MIN.
610 mm MIN.
DISCHARGE
TERMINATION
CAP
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Angle
H (Min.) mm
0°-26.6° .......................500*
26.6°-30.3° ..................500*
30.3°-33.7° ..................500*
33.7°-36.9° ..................610*
36.9°-39.8° ..................760*
39.8°-42.5° ................... 990
*910 mm minimum in snow regions
Figure 8.5 Minimum Height from Roof to Lowest Discharge
Opening
To prevent odors and cold drafts, the chimney must be sealed around the vent with non-combustible blanket insulation or
fi eld fabricated metal plates.
Masonry
APPLY SEALANT
EXHAUST
VENT PIPE
Figure 8.7
26
HORIZONTAL
OVERHANG
VERTICAL
WALL
LOWEST
OPENING
X
305 mm
ROOF PITCH
IS X/ 305 mm
Angle
H (Min.) mm
42.5°-45.0° ................. 1220
45.0°-49.4° ................. 1520
49.4°-53.1° ................. 1830
53.1°-56.3° ................. 2130
56.3°-59.0° ................. 2290
59.0°-60.3° ................. 2440
LINK-DV30B
Installation
TERMINATION
CAP
AIR
SEAL GAP
AROUND FLEX PIPE
Note: Untwist the pipe
while extending it, to
achieve full 30 ft (9 m)
length.
INLET AIR
VENT PIPE
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. V • 6/14
CAUTION! Risk of Cuts/Abrasions/Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
Damper Flashing Kit (Optional)
For use with LINK-DV30B Liner Kit.
Note: Damper may have to be removed to use this kit.
• Run fl ex liners through 3 in. (76 mm) holes in damper
fl ashing.
• Attach damper fl ashing to fi rebox roof with self tapping
screws included in kit.
CLASS A PIPE
FLASHING
Figure 8.6
Factory Built
Wood Burning
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WOODBURNING PIPE
Remove 18 in. x 18 in. (457 mm x 457 mm) fl ashing on cap by remov-
ing 3 screws. Connect both the LINK-ZC-ADPB to Class A Pipe and
the termination cap to the LINK-ZC-ADPB with the self tapping screws
provided.
APPLY SEALANT