UTILITY SERVICE LAYOUT

Gas and electrical services for the Models 1116 and 1117 should be located as shown below. If flexible services
are provided, they must meet code requirements for such installation.
Back view of two Impinger
Gas Valve Installation and piping spacing.
INSTALLATION CODES AND GUIDELINES
GAS INSTALLATION
Safe and satisfactory operation of this oven depends to a great extent upon its proper installation, and it should be
installed, as applicable in accordance with the National Fuel Gas Codes, ANSI Z223.1/NFPA 54 latest version,
Manufacturers' Installation Instructions and local municipal building codes, ISO 203-1.
1. The oven and its individual shut off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psig (3.45kPa).
2. The oven must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply system at test pressures equal to or less than ½
psig (3.45kPa).
IN MASSACHUSETTS: The minimum length of a flexible gas supply hose is thirty-six (36") inches.
IN CANADA: The installation of these appliances is to be in accordance with CSA B.149.1 latest version – Natural
Gas and Propane Installation Code – and/or Local Codes.
IN AUSTRALIA: Adhere to AG 5601-2004 and 4563-2004 Gas Installation Code.
10
®
II Gas Ovens showing
Back view of three Impinger
Gas Valve Installation and piping spacing.
Impinger II – Digital Advantage Ops Manual –Dom & Int'l
®
II Gas Ovens showing