Electrical Service; General Information - Lincoln Impinger 1600 Series Specification Sheet

1600 series low profile single belt conveyorized oven
Hide thumbs Also See for Impinger 1600 Series:

Advertisement

Gas Supply Pressure Recommendations:
Gas Type
Natural
LP
*Gas supply pressures are dependent on local gas type and on all applicable local codes. Agency approved flexible
connection to each oven must be minimum¾" (19 mm) NPT and length must not exceed six (6) feet (1829 mm).

Electrical Service:

Each oven deck requires voltage, phase and hertz as indicated by model number. Neutral must be grounded
at electrical service and receptacle properly polarized. Gas 120V units have a cord with NEMA 5-15 plug.
All other models have terminal block connections. It is recommended that a separate circuit breaker be
provided for each oven deck.
Recommended Minimum Clearances:
Rear of oven to combustible surface: 6" (152 mm). Clearance on each side from other cooking equipment: 24"
(610 mm). Clearance required to remove conveyor for cleaning: 11' (3553 mm).
Warranty:
All new impinger
ovens installed in the United States and Canada come with a one (1) year parts and labor
®
warranty starting from the date of start-up/check-out. All ovens installed in locations other than the US and
Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out. Start-up/check-out must occur within 24 months of date of manufacture.

General Information:

Length
All 1600 Models
(2032 mm)
Model
Agency
Number
1600-000-U
NSF/CSA
1633-000-E
NSF/AGA/CE
1635-V00-E
--
1601-000-U
NSF/CSA
1634-000-E
NSF/AGA/CE
1636-V00-E
--
1621-000-E
CE
1622-000-U
UL/NSF
1623-000-U
UL/NSF
1624-000-U
UL/NSF
1628-000-N
--
1629-000-N
--
1637-000-E
CE
NOTE: Panel setups are added as kit numbers to the end of the model number to complete the oven order; (example: 1600-000-U-K1819 is a 1600-000-U with
standard setup, left to right.)
Supply (Inlet) Pressure (mbar)
9-14" WC (2.2 kPA / 22.4 mbar - 3.5kPa / 34.9 mbar)
11-14" WC (2.7 kPa / 27.36 mbar - 3.5 kPa / 34.9 mbar)
Depth
80"
60 ¹/₂"
(1537 mm)
Utility
Input Rate
Natural
Natural
110,000 BTU
Natural
32.2 kW
LP
(116 MJ)
LP
LP
Electric
Electric
Electric
Electric
29 kW
Electric
Electric
Electric
Global
Height
Height
Single
Double Stacked
44 ¹/₈"
63 ³/₈"
(1121 mm)
(1610 mm)
Voltage
Hertz
120
60
230
50
220
60
120
60
230
50
220
60
400/230
50
120/208
60
120/240
60
120/220
60
380/220
50
415/240
50
215/240
50
Recommended
Minimum
Gas Pipe Size
2" (51 mm)
2" (51 mm)
Height
Triple Stacked
66 ³/₈"
(1686 mm)
Phase
Supply
1
3
1
3
1
5
1
3
1
3
1
5
3
5
3
5
3
5
3
5
3
5
3
5
3