Utility Specifications - Gas & Electric; Impinger Ii – Digital Advantage Ops Manual –Dom & Int'l - Lincoln Series 1100 Installation And Operating Instructions Manual

Advantage conveyor ovens series 1100
Hide thumbs Also See for Series 1100:
Table of Contents

Advertisement

Model
Energy
1130/60
Electric
1131/61
Electric
1132/62
Electric
1133/63
Electric
1130-080-A
Electric
1131/61-080-A
Electric
1132/62-080-A
Electric
1133-080-A
Electric
1134
Electric
1135
Electric
1136
Electric
1151
Electric
*1164-XXX-E
Electric
1130-000-A
Electric
1131-000-A
Electric
1132-000-A
Electric
1133-000-A
Electric
1130-08H-A
Electric
1131-08H-A
Electric
1132-08H-A
Electric
1133-08H-A
Electric
* REF MODEL NUMBER KEY
Model
Energy
Power
1116
Nat. Gas
40,000 BTU
1117
L.P. Gas
40,000 BTU
1154
Nat. Gas
45 MJ
1155
L.P. Gas
45 MJ
1156
Town
45 MJ
1157
Nat. Gas
40,000 BTU
1158
L.P. Gas
40,000 BTU
*1154-XXX-E
Nat. Gas
12kW
*1155-XXX-E
L.P. Gas
12kW
1116-000-A
Nat. Gas
40,000 BTU
1117-000-A
L.P. Gas
40,000 BTU
1116-080-A
Nat. Gas
40,000 BTU
1117-080-A
L.P. Gas
40,000 BTU
GAS PRESSURE CONVERSION CHART
Inches of
KPa
m-Bar
Water Column
3.5
0.87
8.70
4.5
1.12
11.2
7
1.74
17.40
10
2.48
24.87
10.5
2.61
26.11
11
2.73
27.36
14
3.48
34.81
14.5
3.61
36.05
4
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC
Power
Voltage
Current
10kW
120/208 VAC
48 Amps
10kW
120/240 VAC
42 Amps
10kW
120/208 VAC
28 Amps
10kW
120/240 VAC
25 Amps
10kW
120/208 VAC
48 Amps
10kW
120/240 VAC
42 Amps
10kW
120/208 VAC
28 Amps
10kW
120/240 VAC
25 Amps
10kW
380Y/208 VAC
15 Amps
10kW
415Y/240 VAC
14 Amps
10kW
240 VAC
42 Amps
10kW
200VAC
29 Amps
10kW
400/230 VAC
15 Amps
10kW
208 VAC
48 Amps
10kW
240 VAC
42 Amps
10kW
208 VAC
28 Amps
10kW
240 VAC
25 Amps
12kW
208 VAC
63 Amps
12kW
240 VAC
54 Amps
12kW
208 VAC
36 Amps
12kW
240 VAC
31 Amps
UTILITY SPECIFICATIONS REQUIRED – GAS
Voltage
Current
Phase
120 VAC
7 Amps
1
120 VAC
7 Amps
1
240 VAC
2 Amps
1
240 VAC
2 Amps
1
240 VAC
2 Amps
1
220/240 VAC
2 Amps
1
220/240 VAC
2 Amps
1
230 VAC
2 Amps
1
230 VAC
2 Amps
1
120 VAC
7 Amps
1
120 VAC
7 Amps
1
120 VAC
7 Amps
1
120 VAC
7 Amps
1
* AGA – Australia Gas Association (See 1154 & 1155 above)
Millimeters of
** NOTE: For proper operation, the gas valve requires a nominal inlet pressure of 7 inches of H
Water Column
for L.P. gas. A minimum inlet pressure of 1.0 inch of H
88.9
must be maintained with no pressure drop from the no load to full load condition. The maximum inlet pressure must be maintained at or below
½ PSIG (14.5 inches H
114.3
177.8
Electrical Supply for Australia:
254.0
Single Phase: 240 VAC, 50 Hz / 20 Amp; one neutral & one earth/ground.
266.7
Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.
279.4
355.6
All ovens require separate service and dedicated neutral.
368.3
NOTE: Do not install the (these) oven(s) in any area with an ambient temperature in excess of 95°F / 35° C. Doing so will cause damage to the
unit.
Recommended
Phase
Hz
Electrical Specification
1
60 Hz
4 Wires, 2 Pole + N + G
1
60 Hz
4 Wires, 2 Pole + N + G
3
60 Hz
5 Wires, 3 Pole + N + G
3
60 Hz
5 Wires, 3 Pole + N + G
1
60 Hz
4 Wires, 2 Pole + N + G
1
60 Hz
4 Wires, 2 Pole + N + G
3
60 Hz
5 Wires, 3 Pole + N + G
3
60 Hz
5 Wires, 3 Pole + N + G
3
50 Hz
5 Wires, 3 Pole + N + G
3
50 Hz
5 Wires, 3 Pole + N + G
1
50 Hz
3 Wires, 1 Pole + N + G
3
60 Hz
4 Wires, 3 Pole + G
3
50 Hz
5 Wires, 3 Pole + N + G
1
60 Hz
3 Wires, 2 Pole + G
1
60 Hz
3 Wires, 2 Pole + G
3
60 Hz
4 Wires, 3 Pole + G
3
60 Hz
4 Wires, 3 Pole + G
1
60 Hz
3 Wires, 2 Pole + G
1
60 Hz
3 Wires, 2 Pole + G
3
60 Hz
4 Wires, 3 Pole + G
3
60 Hz
4 Wires, 3 Pole + G
Recommended
Recommended
Hz
Electrical Specification
Circuit Breaker
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
50 Hz
3 Wires, 1 Pole + N + G
50 Hz
3 Wires, 1 Pole + N + G
50 Hz
3 Wires, 1 Pole + N + G
50 Hz
3 Wires, 1 Pole + N + G
50 Hz
3 Wires, 1 Pole + N + G
50 Hz
3 Wires, 1 Pole + N + G
1 Pole, 16 Amp
50 Hz
3 Wires, 1 Pole + N + G
1 Pole, 16 Amp
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
60 Hz
3 Wires, 1 Pole + N + G
1 Pole, 15 Amp
O column above the manifold setting (NAT. manifold 3.5" H
2
O column). Refer to the chart on the left for pressure conversions.
2
Recommended
Supply Wire
Circuit Breaker
Size 90° C
2 Pole, 50 Amp
6 AWG
2 Pole, 50 Amp
8 AWG
3 Pole, 30 Amp
10 AWG
3 Pole, 30 Amp
10 AWG
2 Pole, 50 Amp
6 AWG
2 Pole, 50 Amp
8 AWG
3 Pole, 30 Amp
10 AWG
3 Pole, 30 Amp
10 AWG
2
5 x 2.5mm
2
5 x 2.5mm
2
3 x 10.0mm
2
3 x 4.0mm
2
3 Pole, 32 Amp
5 x 2.5mm
2 Pole, 50 Amp
6 AWG
2 Pole, 50 Amp
8 AWG
3 Pole, 30 Amp
10 AWG
3 Pole, 30 Amp
10 AWG
2 Pole, 90 Amp
4 AWG
2 Pole, 50 Amp
6 AWG
3 Pole, 70 Amp
8 AWG
3 Pole, 40 Amp
10 AWG
Gas
40,000 BTU at 7 inches, H
O column**
2
40,000 BTU at 11 inches, H
O column**
2
45 MJ/HR at 1.7 kPa, H
O column**
2
45 MJ/HR at 2.73 kPa, H
O column**
2
45 MJ/HR at 3.6 kPa, H
O column**
2
40,000 BTU at 7 inches, H
O column**
2
40,000 BTU at 11 inches, H
O column**
2
12 kW/HR at 17.4 mB, H
O column**
2
12 kW/HR at 27.4 mB, H
O column**
2
40,000 BTU at 7 inches, H
O column**
2
40,000 BTU at 11 inches, H
O column**
2
40,000 BTU at 7 inches, H
O column**
2
40,000 BTU at 11 inches, H
O column**
2
O for natural gas and 11 inches of H
2
O, L.P. manifold 10" H
2
Impinger II – Digital Advantage Ops Manual –Dom & Int'l
Agency Listings
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
NSF
NSF
NSF
NSF
CE, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, CSA, NSF
UL, cUL, NSF
UL, cUL, NSF
UL, cUL, NSF
UL, cUL, NSF
Agency Listings
CSA, NSF
CSA, NSF
AGA*, NSF
AGA*, NSF
AGA*, NSF
NSF
NSF
CE, NSF
CE, NSF
CSA, NSF
CSA, NSF
CSA, NSF
CSA, NSF
O column
2
O)
2