Vertex Standard VXA-300 PILOT III Operating Manual page 48

Air band transceiver
Hide thumbs Also See for VXA-300 PILOT III:
Table of Contents

Advertisement

01 SQL
Function: Squelch Level Setting.
Available Values: 0 ~ 8
Default Setting: 6
Select a setting for this Menu item which just silences the
receiver when no signal is present. Use the lowest setting
which will keep the receiver quiet between incoming trans-
missions.
02 MCLR
Function: Memory Channel Clear ("MR" memory only).
To clear a Memory channel:
Select the Menu Item MCLR.
Press the VOLUME knob, then rotate the DIAL se-
lector knob to recall the memory channel to be erased.
Press the VOLUME knob to clear the Memory chan-
nel (the Memory channel number will return to
"001").
Important Notice: An "erased" channel cannot be restored,
and "CH-001" cannot be erased, as it is used for "Priority
Channel" operation.
46
M
"S
" M
ENU
ET
03 RESM
Function: Scan-Resume Mode Setting.
Available Values: 5S/CAR
Default Setting: 5S
"5S" (5-Second Pause) mode: the scanner will halt for
five seconds only, after which scanning will resume
(whether or not the other station is still transmitting).
"CAR" (Carrier Drop) mode: the scanner will remain
halted for as long as there is a carrier present on the chan-
nel; after the carrier drops at the end of the other station's
transmission, the scanning will resume.
04 SCNL
Function: Scan Lamp On/Off (while paused).
Available Values: on/oFF
Default Setting: on
If you set this function to "on," the lamp will be illumi-
nated whenever the scanner pauses. The lamp will go off
automatically when scanning resumes.
VXA-300 P
ODE
O
ILOT
PERATING
M
ANUAL

Advertisement

Table of Contents
loading

Table of Contents