Electrical Connection - Electra Monoblock 7 Service Manual

Cooling only indoor & outdoor units
Hide thumbs Also See for Monoblock 7:
Table of Contents

Advertisement

CONNECTING THE UNITS (See Figures 12 and 13)
After locating outdoor and indoor unit in their respective places, perform the following steps to reconnect between
the two units:
Remove protection plugs (16), (18) and covers (15), (17) from their respective connectors (see Figure
STEP 1.
13).
STEP 2.
Connect quick disconnect (5) to its mating part (6), as follows:
- Turn by hand part (5) onto part (6).
- Retain lock-nut (13) with the supplied wrench No. 2 (20) and close with the supplied wrench
No. 1 (19) the hexagonal nut (5) to its mating part (6), until it is tight.
Do not use excessive force to tighten the nut.
WARNING:
STEP 3.
Connect quick disconnect (7) to its mating part (8) as follows:
- Turn by hand part (7) onto part (8).
- Retain lock-nut (14) with the supplied wrench No. 2 (20) and close with the supplied wrench No. 1
(19) the hexagonal nut (7) to its mating part (8), until it is tight.
Do not use excessive force to tighten the nut.
WARNING:
STEP 4.
Reconnect interconnecting hose clamp (21) with its screws to the unit.
STEP 5.
Connect the drain hose (9) to the drain pan (10).
Connect the electrical plug (3) by pressing it into its socket (4).
STEP 6.
Reconnect the tubes clamps (12) with its fastening screw.
STEP 7.
Reinstall the cover (1) and tighten it with its fastening screw (2).
STEP 8.
STEP 1
Figure 13

ELECTRICAL CONNECTION

Before plugging in, please check that:
1. Socket and mains correspond to data given in specifications.
2. Plug fits the socket; if not, change socket.
3. Socket is properly grounded.
The manufacturer is not responsible for any damage incurred due to failure of following normal safety
procedures.
STEP 5
STEP 6
STEP 7
STEP 3
STEP 4
STEP 2
English 9
APPENDIX A
STEP 8
Figure 12