Electrical Data - Electra Delta 22 Service Manual

Dc inverter delta series
Hide thumbs Also See for Delta 22:
Table of Contents

Advertisement

7.

ELECTRICAL DATA

7.1
Single Phase Units
MODEL
Power Supply
Max Current, A
Circuit Breaker,A
Power Supply
Wiring No. X Cross Section mm
Interconnecting Cable RCModel
Wiring No. X Cross Section mm
MODEL
Power Supply
Max Current, A
Circuit Breaker,A
Power Supply
Wiring No. X Cross Section mm
Interconnecting Cable RC Model
No. X Cross Section mm
(a) The Inrush current is the current when power is up (charging the DC capacitors of
the outdoor unit controller).
(b) Starting current is the current when starting the compressor.
Power wiring cord should comply with local lows and electrical regulations
requirements.
Service Manual - Delta DCI
Delta 22
To indoor
1PH,220-240V,50Hz
5.2
12
3x1.0 mm
2
4x1.0 mm
2
Delta 50
To indoor
1PH,220-240V,50Hz
10.3
20
3x1.5 mm
2
4x1.5 mm
2
NOTE
Revision Y05-02
CONTENT
Delta 25
To indoor
1PH,220-240V,50Hz
6.3
12
2
3x1.0 mm
2
4x1.0 mm
Delta 35
To indoor
1PH,220-240V,50Hz
7.5
15
2
3x1.5 mm
2
5x1.5 mm
ELECTRICAL DATA
2
2
2
2
7-1
DELTA DCI

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Delta 25Dcr 22Delta 35Dcr 35Dcr 25Delta 50 ... Show all