INSTALLATION

This mobile split air conditioner can be installed by the customer, as follows:
Choose an appropriate place for the air conditioner indoor unit near an exterior opening (window or door). A
grounded 230 electrical outlet should be within 2.5 meters of the indoor unit.
Determine whether the outdoor unit is to be suspended from the window of the wall, or placed on the floor near
a doorway. Be sure the outdoor unit is stable and well supported at its place of installation (see Figure 5).
The outdoor unit must be installed with the rear grille facing the wall at a minimum distance of 60 mm.
Be sure the outdoor unit is stable and well supported at its place of installation so that its handle and hose are
on top. To assure proper condensed drainage, make sure the unit is installed in a level position.
Under high humidity conditions, the outdoor unit condensate basin (6) may overflow. If this occurs often, it is
recommended to use a permanent drain tube by fitting a 13-mm OD tube (7), routed to a nearby drainage point.
2
5
3
6
7
4
Model 3.1 KW (R407C)
1. Indoor unit
2. Window
3. Outdoor unit, wall mounted
4. Outdoor unit, floor mounted
5. Interconnecting hose
8
1
Figure 5
6. Condensate basin
7. Overflow drain tube
8. Spacing stud
English 5
APPENDIX A
2
5
8
3
1
6
7
4
Model 4.1 KW (R22/R410A)
3.1 KW (R410A)