en | On-Screen Display (OSD) Menus (Bosch Protocol)
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined.
YES to enable or NO to disable (default setting)
Input
Toggles through a list of valid inputs set in the Alarm I/O Setup > Inputs Setup Menu that
defines the rule's inputs. A rule can have up to four (4) inputs.
Inputs which were set in the Inputs Setup Menu include Aux On/Off (1–99), Shot, and NONE
(default setting).
Output
Toggles through a list of valid outputs set in the Alarm I/O Setup > Outputs Setup Menu that
defines a rule's outputs.
Outputs set in the Outputs Setup Menu include Alarm Relay, Aux On/Off (1–9), Shot, OSD,
Transmit, and NONE (default setting).
Some outputs, such as Alarm Outputs 1–2 and Aux On/Off can be set to be active for a
specific duration of time as follows:
Seconds: 1–5, 10, 15, or 30
Minutes: 1–5 or 10
Latched: The alarm stays active until acknowledged.
Follows: The alarm follows the alarm rule.
Default setting: NONE
Notice!
You can include up to four (4) Input and Output events in a single rule. Each input and
output, however, must be true for the alarm's rule to be valid and enabled.
13.7

Language Menu

The Language Menu contains a list of languages in which the on-screen menus are available.
Language
Exit...
English
Spanish
French
November 2011 | | F.01U.239.454