Heat pump, Split, single service
Line
Function
6741 S
Temperature alarm initiation CC2
6745 S
DHW load alarm
6746 S
Temperature alarm initiation Cold 1
6800 S
History 1
6802 S
History 2
6804 S
History 3
6806 S
History 4
6808 S
History 5
6810 S
History 6
6812 S
History 7
6814 S
History 8
6816 S
History 9
6818 S
History 10
Maintenance / special regime
7070 I
Interval time for maintenance HP
7071 I
Operating time HP since last maintenance.
Reset ? (no, yes)
7072 I
Maximum number of starting of the compressor 1,
authorized per hour of operation.
7073 I
Average number of starts of the compressor per hour of
operation, since the 6 last weeks.
Reset ? (no, yes)
7076 I
Maximum discrepancy condens / week
7077 I
Current maximum discrepancy condens / week
Reset ? (no, yes)
7078 I
Minimum discrepancy condens / week
7079 I
Current minimum discrepancy condens / week
Reset ? (no, yes)
7090 I
DHW tank period
7091 I
DHW tank since maintenance
Reset ? (no, yes)
7092 I
Heat pump DHW min load temperature
7141 U
Emergency regime
Off: The heat pump does not use the backup electrical heating system or the boiler connection when a fault occurs (error
370)
ON: The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error 370).
In the "ON" position, the energy costs can be onerous if the error is not eliminated.
7142 S
Emergency service operating type
Manual: Emergency mode is not active when a fault occurs. (Emergency mode = OFF)
Automatic: Emergency mode is active when a fault occurs. (Emergency mode = ON)
In automatic position, the energy cost can be onerous if the error is not detected and eliminated.
7150 I
Outside temperature simulation
7181 I
Contact's telephone 1
7183 I
Contact's telephone 2
42
Setting range
or display
---, 10... 240 min
---, 1... 48 h
---, 10... 240 min
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
--- , 1... 240
0... 240
--- , 0,1 ... 12
0 ... 12
--- , 1... 250
0... 250
--- , 1... 250
0... 250
--- , 1... 240
0... 240
5... 80 °C
Off, ON
Manual, Automatic
--- , -50 ... 50 °C
0 ... 255
0 ... 255
Installation and operating manual "1350-EN"
Setting
Basic
setting
increment
10 min
---
1 h
---
10 min
---
1 Month
---
1 Month
0
0,1
---
0
1
---
1
---
0
1 Month
---
0
1
5 °C
Off
Manual
0,5
---