Fujitsu AOYA18LALL Installation And Operating Manual page 41

Heat pump air/water split single service
Hide thumbs Also See for AOYA18LALL:
Table of Contents

Advertisement

Heat pump, Split, single service
Line
Function
2920 S
With electrical utility lock (EX4)
Released : HP = ON _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _ Boiler = ON
Locked : HP = off _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _ Boiler = ON
Additional generator (Boiler connection)
3700 S
Release under outside temperature
3705 I
Time delay on stopping
Domestic hot water (DHW) (Only with the DWH kit option)
5020 S
Overheight initial setting
5024 S
Differential
5030 S
Limitation on load duration
5060 S
Electrical resistance regime
5061 S
Release of electrical resistance
Installation configuration
5700 I
Pre-setting
This control enables you to choose one of the 8 pre-selected installation configurations. The hydraulic layouts for
the various configurations are detailed in the section: "Installation Configurations".
– Pre-setting 1 : 1 heating circuit
– Pre-setting 2 : 1 heating circuit and DHW tank.
– Pre-setting 3 : 2 heating circuits.
– Pre-setting 4 : 2 heating circuits and DHW tank.
– Pre-setting 5 : Boiler connection and 1 heating circuit.
– Pre-setting 6 : Boiler connection and 2 heating circuits
– Pre-setting 7 : Boiler connection, 1 heating circuit and DHW tank.
– Pre-setting 8 : Boiler connection, 2 heating circuits and DHW tank.
– Pre-setting 9 to 12 : Do not use for heat pump model "S". Reserved only for heat pump model "Duo"
5711 S
Cooling circuit 1
5870 S
Combined DHW tank
6046 I
Function input H2
1 - Operating mode change HCs + DHW
2 - Operating mode change HCs
3 - Operating mode change HC1
4 - Operating mode change HC2
6 - Error/alarm message
9 - Dew point monitoring
16 - Swimming pool release
6047 I
Contact type H2
NC - Normally-closed, NO - Normally-opened
6100 S
Outside temperature sensor correction
6120 S
Installation frost-free mode
6205 S
Re-initialise parameters
6220 S
oftware version (RVS)
Error
6711 U
Heat pump Reset
6740 S
Temperature alarm initiation CC1
Installation and operating manual "1350-EN"
Setting range
or display
Locked, Released
--- , -50 ... 50 °C
0 ... 120 min
0 ... 30°C
0 ... 20°C
10 ... 600 min
Replacement, Summer,
Always, Cooling regime
24h/day, Release of DHW,
Programme 4/DHW
1,2,3...12
Off, System with 4 tubes,
System with 2 tubes
no, yes
1 ... 16
NC, NO
-3 ... 3 °C
ON, Off
No, yes
0...99
No, yes
---, 10... 240 min
Setting
Basic
setting
increment
Released
0,5 °C
2 °C
1 min
20
1 °C
5 °C
1 °C
7 °C
10 min
90 min
Replacement
Release of
DHW
1
1
Off
No
1
9
NO
0,1 °C
0 °C
ON
No
0
No
10 min
---
41