Fujitsu AUYA30LBLU Service Manual

Fujitsu AUYA30LBLU Service Manual

Split type air conditioner cassette type (50hz

Advertisement

SPLIT TYPE
AIR CONDITIONER
CASSETTE TYPE (50Hz)
Indoor unit
AUYA30LBLU
AUYA36LBLU
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . .
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . .
INDOOR PCB CIRCUIT DIAGRAM . . . . . . .
OUTDOOR PCB CIRCUIT DIAGRAM
ERROR CONTENTS . . . . . . . . . . . . . . . . . .
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . .
AOYA30LBTL
AOYA36LBTL
1
2
4
5
6
10
. . . . .
15
17
. . . . . . . . . . . . . . .
24
. . . . . . . . . . . . .
28

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AUYA30LBLU

  • Page 1: Table Of Contents

    SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit AUYA30LBLU AOYA30LBTL AUYA36LBLU AOYA36LBTL CONTENTS SPECIFICATIONS ..... . DIMENSIONS ......
  • Page 2: Specifications

    SPECIFICATIONS ELECTRICAL DATA COMPRESSOR AND REFRIGERANT TYPE Cooling & Heating Hermetic type, Inverter, COMPRESSOR TYPE 4 poles, 3 phase, AUYA30LBLU AUYA36LBLU INDOOR UNIT DC motor, Twin Rotary OUTDOOR UNIT AOYA30LBTL AOYA36LBTL DISCRIMINATION 5KD240XAD21 COOLING CAPACITY 8.5 kW 10.0 kW 16.3 kg...
  • Page 3: Dimensions

    DIMENSIONS Drain pipe INDOOR UNIT DECORATION PANEL (Unit : mm) Gas pipe Liquid pipe Drain pipe diameter Side view Inside : 20 mm Outside : 26 mm Bottom view Bottom view 795 (Hanging bolt position) Top view 2009.01.28...
  • Page 4 OUTDOOR UNIT (Unit : mm) Air Flow 2008.01.18...
  • Page 5: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM Refrigerant direction : Cool : Heat INDOOR UNIT OUTDOOR UNIT Pressure Refrigerant Pipe Check Valve 15.88mm (5/8") High Pressure Charging Switch Valve 4-way Condenser Evaporator Valve Accumulator Compressor Refrigerant Pipe 9.52mm (3/8") Strainer Strainer Expansion Valve Charging Valve 2008.01.28...
  • Page 6: Circuit Diagram

    CIRCUIT DIAGRAM INDOOR UNIT OUTDOOR UNIT BLACK HIGH PRESSURE SWITCH THERMISTOR ( PIPE TEMP. ) BLACK CN90 THERMISTOR ( COMPRESSOR TEMP. ) THERMISTOR ( ROOM TEMP. ) BROWN FLOAT SWITCH CN64 BROWN CN42 CN40 CN200 CN400 1 2 3 4 5 1 2 3 4 5 6 7 8 9 1 2 3 4 THERMISTOR ( OUTDOOR TEMP.
  • Page 7 PCB Circuit Diagrams not available at time of publication...
  • Page 8: Error Contents

    ERROR CONTENTS TROUBLESHOOTING AT A REMOTE CONTROL LCD You will find this on a wired remote control LCD. (option) If an error occurs, the following display will be shown. ("EE" will appear in the set room temperature display.) If "CO" appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control.
  • Page 9 OUTDOOR UNIT SPECIAL INSTALLATION SETTING CAUTION Always turn on the power 12 hours prior to the start of the PUMP DOWN (Refrigerant collecting operation) operation in order to ensure compressor protection Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.
  • Page 10: Parts (Indoor Unit)

    PARTS DECORATION PANEL UTG-UGYA-W Ref. Description Part number Intake Grille Assy 9378565012 Long Life Filter 9378252011 Filter Guide 9378253018 Hook Bracket 9378435018 Grille Hook 9378250017 2008.06.24...
  • Page 11 DECORATION PANEL UTG-UGYA-W Ref. Description Part number Decoration Panel 9378242012 Corner Panel A 9378243019 Corner Panel A 9378243026 Receiver Window 9375547011 PCB Holder 9378246010 PCB Sube Assy 9707372021 PCB Cover 9378245013 Panel Cover A 9378261013 Panel Cover B 9378262010 Drain Cover 9378359017 2008.06.24...
  • Page 12 DECORATION PANEL UTG-UGYA-W Motor holder assy Ref. Description Part number Flap 9378254015 Poli Slider 9375541019 Joint C 9378357013 Step motor 9900467005 Gear A 9378256019 Motor Holder 9378255012 Joint A 9378258013 Joint B 9378259010 Gear B 9378257016 Joint Shaft 9378260016 Flap Spring 9378356016 Wire (Step Motor) 9707869019...
  • Page 13: Parts (Outdoor Unit)

    PARTS INDOOR UNIT Ref. Description Part number Cabinet C 9378196018 Hook R 9378197015 Hook L 9378198012 Turbo Fan Assy 9378228016 Motor, DC Brushless 9602716005 Rubber (Motor) 9378223011 2008.06.25...
  • Page 14 INDOOR UNIT Ref. Description Part number Evaporator Total Assy 9378580015 Coupling Pipe Assy 9373038481 Distributor Assy 9371325446 2008.06.24...
  • Page 15 INDOOR UNIT Ref. Description Part number Sensor Holder 9378329010 Float Switch 9900465018 Pump Assy 9900464011 Drain Pump Holder B 9375518011 Rubber (Pump) 9378426016 Drain Hose 9378212015 Drain Port 9378213012 Drain Pan Assy 9378207011 Bell Mouth 9378227019 Terminal Wire Cover 9378548015 Drain Cap 9375502010 Drain Hose Assy...
  • Page 16 INDOOR UNIT Ref. Description Part number PCB Holder 9378205017 Power PCB Assy 9707398083 Controller PCB Assy (30) 9707393316 Controller PCB Assy (36) 9707393323 Clamp 9378237018 Terminal 3P 9306489045 Terminal 3P 9703345012 Thermistor Holder A 9378206014 Thermistor Holder B 9378330016 Room Thermistor 9900445010 Pipe Thermistor 9900470012...
  • Page 17: Outdoor Unit

    OUTDOOR UNIT Ref. Description Part number Top Panel Sub Assy 9374417032 Front Panel 9374094066 Fan Guard 9374330010 Grip Side 9374173013 Service Panel Sub Assy 9374415052 Right Panel Sub Assy 9374416127 Emblem Rear 9351355005 Valve Cover 9374174010 2008.04.24...
  • Page 18 OUTDOOR UNIT Ref. Description Part number Base Assy 9374166138 Condenser A Assy 9374433056 Separate Wall 9374413188 Fan Motor 9602717019 Propeller Fan Assy 9366378020 2008.04.24...
  • Page 19 OUTDOOR UNIT Ref. Description Part number Accumulator 9385005006 4-Way Valve 9900164010 Solenoid 9970055034 Pressure Switch 9900186012 Compressor Assy 9372558126 Accumulator Support Assy 313986353804 Check Joint Assy 9372802038 Expansion Valve Assy 9370947144 Coil (Expansion Valve) 9900057039 3-Way Valve Assy 9377959010 3-Way Valve Assy 9377958013 Inlet Pipe (Cond) A Assy 9373461067...
  • Page 20 OUTDOOR UNIT Ref. Description Part number Inverter Case 9375314019 TR PCB Assy (IPM) 9707669039 ACTPM 9707592016 Choke Coil 9900366018 Capacitor PCB Assy 9707257021 PCB Case Assy 9375316020 Controller PCB Assy (30) 9707667059 Controller PCB Assy (36) 9707667066 Power Supply PCB Assy 9707128161 Terminal 9900203023...
  • Page 21: Accessories

    ACCESSORIES INDOOR UNIT OPTIONAL PARTS Name and Shape Q'ty Application Name and Shape Model name Application Template For installing indoor unit Wired remote (Carton top) UTB-YUD Control unit on wall contro Washer For installing indoor unit Air outlet shutter plate Install the plate at outlet UTR-YDZC when carrying out 3-way...
  • Page 22 0804G3413...

This manual is also suitable for:

Aoya30lbtlAoya36lbtlAuya36lblu