1.3 Operating conditions
Operating range:
air temperature of between 5 °C and 38 °C for standard models,
air temperature of between ‐8 °C and 38 °C for D models,
water temperature of between 10 °C and 32 °C,
Maximum temperature of 32°C to protect the pool liner.
The D version also features a de‐icing function by using forced ventilation or reversed cycle.
1.4 Technical specifications
Z300
Voltage
M4
230V‐50Hz
M5
230V‐50Hz
T5
400V‐50Hz
M7
230V‐50Hz
MD5
230V‐50Hz
TD5
400V‐50Hz
MD8
230V‐50Hz
TD8
400V‐50Hz
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% (according to French standard NF‐
414)
protection class: IP 24
refrigerant gas: R410A
refrigerant charge: see product information plate
2. Installation
Do not take grip on the outer casing to pick up the device, hold the base.
2.1 Access to the technical compartment
2.2 Selecting an installation site
The device must be installed outdoors and there must be adequate open space surrounding it (see
§2.4).
the heat pump must be installed at a certain distance from the pool so as to avoid exposure to water splashes.
The appropriate distance should be defined according to the national electrical standards that apply in the
country of installation (for France: 3.5 meters).
the heat pump must not be installed:
- near a source of heat or inflammable gas,
- near a road/passage where there is a risk of water and mud splashes,
- facing a strong wind,
- with the vent facing toward a permanent or temporary obstacle (window, wall, hedge, etc...), it must be at
least 4 meters from any potential obstacle.
H0439100.A1.EN – 2013/10
Power input*
kW
1.7
2.2
2.2
2.88
2.2
2.2
3.6
3.6
Power output*
kW
7.6
10.4
10.5
13.9
10.7
10.5
15.7
15.7
class: I,
degree of pollution: 2,
overvoltage category: II
Nominal current input*
A
7.9
10.3
4.25
13
10
4.4
16
7.4
COP*
4.5
4.7
4.8
4.8
4.9
4.8
4.5
4.5
3