IDM 98-III / 99-III English
(2) Auto-V
Range
600.0V
DC
1000V
DC
600.0V
AC
1000V
AC
Input Protection : 1000V
AC Frequency Response : 50Hz ~ 1KHz
Input Impedance : Approx. 3kΩ.
AC Conversion Type :
Conversion type and additional specification are same as voltage function.
(3) Current
Range
60.00mA
DC
600.0mA
DC
6.000A
DC
10.00A
DC
60.00mA
AC
600.0mA
AC
6.000A
AC
10.00A
AC
Input Protection : Protected by high energy fuses.
440mA, 1000V AC/DC 10KA Fast acting fuse for mA input. 11A, 1000V AC/DC 20KA Fast
acting fuse for A input
Max. Measuring Time : 3 minutes for "A" input, 10 minutes for "mA" input.
Rest time 20 minutes min.
AC Conversion Type : Conversion type and additional specification are same
as voltage function.
AC Frequency Response : 50Hz ~ 1KHz
IDM98-III/IDM99-III
Resolution
IDM98-III Accuracy
0.1V
1V
0.1V
1V
or 1000V
rms
DC
AC
IDM98-III/IDM99-III
Resolution
IDM98-III Accuracy
0.01mA
0.1mA
0.001A
0.01A
0.01mA
0.1mA
0.001A
0.01A
± (1.0% + 3d)
± (1.0% + 3d)
± (1.0% + 3d)
± (1.0% + 3d)
± (1.0% + 3d)
± (1.5% + 3d)
± (1.5% + 3d)
± (1.5% + 3d)
± (1.5% + 3d)
IDM99-III Accuracy
± (0.80% + 3d)
IDM99-III Accuracy
± (0.8% + 3d)
± (0.8% + 3d)
± (0.8% + 3d)
± (0.8% + 3d)
± (1.2% + 3d)
± (1.2% + 3d)
± (1.2% + 3d)
± (1.2% + 3d)