Kyocera FS-3040MFP+ Service Manual page 263

Hide thumbs Also See for FS-3040MFP+:
Table of Contents

Advertisement

Adjusting the scanner magnification (alternative command for the maintenance mode U065)
Description
Adjusts the magnification of the original scanning.
Purpose
Make the adjustment if the magnification in the main scanning direction is incorrect.
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
Format
!R! KCFG "SCAN",8, #1,#2;EXIT;
Parameter
#1
1: Y SCAN ZOOM Scanner magnification in the main scanning direction
2: X SCAN ZOOM Scanner magnification in the auxiliary scanning direction
#2
#1=1: Adjustable range: -32 to 127 (in 0.1% increment) (0: default)
#2=2 : Adjustable range: -25 to 25 (in 0.1% increment) (0: default)
Example: Y SCAN ZOOM set to 55, X SCAN ZOOM set to 10
!R! KCFG "SCAN",8,1,55; KCFG "SCAN",8,2,10;EXIT;
Original
Original
Copy
Copy
example 2
example 1
Copy
Copy
example 1
example 2
Magnified in the main
scanning direction
Magnified in the auxiliary
scanning direction
2-4-13
2MF/2MG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-3140mfp+

Table of Contents