Installation Instructions

Programming Installer and User Schedules

The system provides up to 32 schedules, which can be used to control various types of system events at
pre-defined times. 24 schedules are intended for use by the end-user, and 8 are reserved for the
installer. In addition, some events are also reserved for the installer only (listed in the "Enter Event"
prompt paragraph below).
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
NOTE: The master code can only access schedules 01-24 and events 00-08.
The following prompts are displayed:
PROMPT
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
NOTE: Events 07 and
10 cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by user code +
OFF.
D E V I C E N U M B E R
XX
G R O U P N U M B E R
X
P A R T I T I O N
X
5-18
VALID ENTRIES
Schedule Number
01-24 = end-user schedules
25-32 = installer-only schedules
[∗] to continue
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to
Pager
04 = Auto (Forced) Stay Arm
05 = Auto (Forced) Away Arm
06 = Auto Disarm
07 = Display "Reminder"
08 = Disarm Time Window
11 = Periodic Test Report
††
12 = Up and About
[∗] to continue
Device Number
01-18 = device number
[∗] to continue
Group Number
1-8 = group number
[∗] to continue
Partition
0 = all partitions
1 = partition 1
2 = partition 2
3 = partition 3
[∗] to continue
EXPLANATION
Enter the desired schedule number.
Enter the desired event number for event you want to occur at a
specified time.
Event 11 is reserved for the installer only.
Child-Not-Home report (option 03) is sent to all pagers in the user's
partition (message sent is 777-7777). User must be enabled for
paging (see User Attributes in System Operation section).
Auto Stay Arm (event 04) and Auto Arm (event 5) cannot be used if
partition 3 is set as a common partition. To use these scheduling
features, field *30 must be 0, making partition 3 a separate partition.
Disarm Time Window (08): System can be disarmed only during this
time period. Exception: If a burglary alarm occurs, the system can be
disarmed outside the scheduled time window.
† If either of these options is selected, Forced Bypass is automatically
enabled regardless of setting in field *23.
††This selection defines the large time window within which the time
window selected in data field *85-entry 2 will be monitored.
This prompt appears if event "1" (relay on/off) was selected, otherwise
it is skipped.
Enter the physical device number as programmed in ∗79 Menu Mode,
then press [*] to continue to the "Start" prompt.
Device numbers 17 and 18 designate built-in triggers 1 and 2
respectively.
This prompt appears if event "2" (user access) was selected.
Otherwise it is skipped.
Press [*] to continue to the "Start" prompt.
This prompt appears if events "3-7,10" were selected. Otherwise it is
skipped.
Press [*] to continue to the "Start" prompt.