Zone Sounds & Timing - Honeywell ADEMCO VISTA-48A Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-48A:
Table of Contents

Advertisement

Installation Instructions
FIELD
TITLE and DATA ENTRIES
Powerline Carrier Device (X-10)
*27
House ID
0 = A
1 = B
2 = C
3 = D
4 = E
5 = F
ECP Contact ID Output for ACM
*29
0 = not used
1 = use Contact ID output on ECP
Make Partition 3 a Common Area
*30
Partition
0 = no (must be 0 if system uses zone type
82 - Blockschloss)
1 = yes, make partition 3 a common area
partition
Zone Sounds & Timing
FIELD
TITLE and DATA ENTRIES
Single Alarm Sounding Per Zone
*31
(per armed period)
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming
period for a given zone
Fire Alarm Sounder Timeout
*32
0 = yes; fire sounder timeout after time
programmed in field ∗33
1 = no fire sounder timeout; continue
sounding until manually turned off
Siren Timeout
*33
0 = No timeout
1 = 1 min
2 = 2 min
3 = 3 min
Exit Delay
*34
00 - 96 = 0 - 96 seconds
97 = 120 seconds
Entry Delay 1
*35
00 - 96 = 0 - 96 seconds
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
Entry Delay 2
*36
See *35 above for entries.
Audible Exit Warning
*37
0 = no; 1 = yes
4-2
6 = G
# + 11 = L
7 = H
# + 12 = M
8 = I
# + 13 = N
9 = J
# + 14 = O
# + 10 = K
# + 15 = P
4 = 4 min
5 = 8 min
6 = 16 min
EXPLANATION
Powerline Carrier devices require a House ID, identified in this field.
Program Powerline Carrier devices in interactive modes ∗79, *80 and
*81.
If selected, all messages programmed to go to the primary telephone
line receiver will also be sent to the connected Alternative
Communication Media (ACM), such as a 7845i Internet/Intranet
Communicator or AI4164RS/AI4164ETH Eureka Network Interface
(sent in Contact ID format). The data line is supervised as well as
certain functions in a long range radio. If communication is lost or a
trouble develops, an attempt will be made to send a message via both
ACM and telephone to the central station.
Program the ACM for device address 3.
If selected, partition 3 functions as a common area partition, rather
than as an independent partition.
Scheduling Note: If partition 3 is set as a common partition, the
scheduling events Auto Stay Arm (event 04) and Auto Arm (event 5)
cannot be used. To use these scheduling features, *30 must be 0.
EXPLANATION
Select whether a zone going into alarm should sound more than once
per armed period.
Select whether fire alarm sounding expires after sounder timeout or
remains until manually turned off.
This field determines whether the external sounder will shut off
after time allotted, or continue until manually turned off.
The system waits the time entered before arming entry/exit zones. If
the entry/exit door is left open after this time expires, an alarm will
occur or the zone will be auto-bypassed, depending on the selection in
field *88. Common area zones use same delay as partition 1.
Upon entering, the system must be disarmed before the time entered
expires, otherwise it sounds an alarm. Common area zones use same
delay as partition 1.
See *35 for explanation.
Warning sound consists of slow continuous beeps until last 10 seconds,
then it changes to fast beeps. Sound ends when exit time expires.