System Status Report Codes

Zone report codes are programmed using interactive ✱ 56 or ✱ 58 Zone Programming modes, while system status
(non-alarm) codes and restore codes are entered in the following data fields. The actual report code digits that
you enter depend upon the particular installation, and should agree with the Central Station office receiving the
signals.
To disable a report code, enter "0" in the first entry.
3+1, 4+1 Standard or Robofon 8 Format: Enter a code in the first entry: 1–9, A, B, C, D, E, or F. Enter #+10
for A (this reports a "0" on some receivers), #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
Entering 0 in the second box advances to the next field.
Expanded or 4+2 Format: Enter codes in both entries (first and second digits) for 1–9 or A–F, as described
above. An entry of "0" in the second entry eliminates the expanded message for that report.
ADEMCO or Robofon Contact ID® Reporting: Enter a digit in the first entry to enable the zone to report.
Use a different digit for each zone until you have used up available digits. If the number of zones exceeds the
number of available digits, begin with digit 1 again. This is an "enabling" code only and is not the actual code
sent to the Central Station office. Entries in the second entry pair are ignored. An entry of 0 in the first box
disables the report.
FIELD
TITLE and DATA ENTRIES
Exit Error Report Code
*59
0 = no report
1-F = report code; see description above
Trouble Report Code
*60
0 = disable; 1-F = see description above ∗59
Bypass Report Code
*61
0 = disable; 1-F = see description above ∗59
AC Mains Loss Report Code
*62
0 = disable; 1-F = see description above ∗59
Low Battery Report Code
*63
0 = disable; 1-F = see description above ∗59
Test Report Code
*64
0 = disable; 1-F = see description above ∗59
Open Report Code
*65
0 = disable; 1-F = see description above ∗59
Intended for use with Alternative Communication Media reporting.
You must also enable field ∗29, ECP Contact ID Output for ACM.
Select the initial reporting destination for messages as follows:
Primary Dialer First selected (0):
• If acknowledged before delay expires (see ∗54), then message will
not be sent to ECP output.
• If not acknowledged before delay expires, then message is sent to
both the Primary Phone No. and ECP output.
ECP Contact ID Output First selected (1):
• If acknowledged before delay expires, then message will not be
sent to the primary dialer.
• If not acknowledged before delay expires, then message is sent to
both the Primary Phone No. and ECP Contact ID output.
EXPLANATION
After arming the system, zones remaining open after exit delay
expires cause an alarm sound at the keypad and external sounder
(keypad also displays "EXIT ALARM"), and entry delay begins.
Disarming before the end of the entry delay stops the alarm sounding
and no message is sent to the central station. The keypad will display
"CA" (fixed-word) or "CANCELED ALARM" (alpha display).
If the system is not disarmed before entry delay expires, an "EXIT
ALARM" message will be sent to the central station if Exit Error
Report Code is enabled. The keypad will display "EA" (fixed-word ) or
"EXIT ALARM" (alpha display), and alarm sounding continues until
the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay,
and an "EXIT ALARM" message will be sent to the central station
With Contact ID format, the message will contain the zone number
and error code 374 ("ALARM–EXIT ERROR").
Sent if a zone has a trouble condition.
Sent when a zone is manually bypassed or is automatically bypassed
at the end of exit delay.
Timing of this report is random with up to a 1-hour delay. If AC mains
restores before the report goes out, there is no "AC RESTORE" report.
Sent when a low-battery condition exists in the system's battery.
Sent periodically to test that the communicator and phone lines are
operational. Frequency of report is set in Scheduling mode (event 11).
Sent upon disarming of the system in the selected partitions.