Installation Instructions

Programming Installer and User Schedules

The system provides 2 schedules (one for the installer, one for the end user), which can be used to
control 11 types of system events at pre-defined times.
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
NOTE: The master code can only access schedules 01 and events 00-07.
PROMPT
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
C L E A R E V E N T 0 0
NOTE: Events 07 and 10
cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by pressing any
key.
D E V I C E N U M B E R
XX
5-14
VALID ENTRIES and EXPLANATION
Enter the desired schedule number.
01 = end-user schedule; 02 = installer-only schedule; 00 = exit scheduling mode
[∗] to continue
Enter the desired event number for event you want to occur at a specified time.
Events 10-11 are reserved for the installer only.
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Latch Key Report to Pager (sent to all pagers and is active only when the system is
armed; message sent is 777-7777; user must be enabled for paging; see User Attributes
in System Operation section)
04 = Forced Stay Arming (forced bypass is automatically enabled regardless of setting in
field *23)
05 = Forced Away Arming (forced bypass is automatically enabled regardless of setting in
field *23)
06 = Auto Disarm
07 = Display "Reminder"
10 = Display custom words (system displays custom words 8, 9, and 10 at defined time; can
be used as installer's reminder message to the end user)
11 = Periodic Test Report (see key commands in Testing the System section to quickly set
periodic test reporting intervals)
[∗] to continue
This prompt appears if event "1" (relay on/off) was selected, otherwise it is skipped.
Enter the physical device number as programmed in ∗79 Menu Mode.
01-04 = device number; 17, 18 = built-in triggers 1 and 2 respectively
[∗] to continue to the "Start" prompt