01 Activated By:
Zone List
"A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Zone List
01-12 = zone list
[∗] to continue
Zone Type
see list at right
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Zone lists 09-12 can be used in output definitions if not used
for paging or for exit zone definition.
Press [∗] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
1
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output.
Press [∗] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
06 = 24 Hr Silent
01 = Ent/Exit #1
07 = 24 Hr Audible
02 = Ent/Exit #2
08 = 24 Hr Aux
03 = Perimeter
09 = Fire
04 = Interior Follower 10 = Interior w/Delay
05 = Trouble Day/
12 = Monitor Zone
Alarm Night
14 = Gas
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
41 = **AC Mains Failure 67 = Siren Fail
21 = Arming–Away
42 = **System Batt Low
22 = Disarming
43 = Comm. Failure
31 = End of Exit Time
46 = Sys Batt Restore**
32 = Start of Entry Time
52 = Kissoff
33 = Any Burglary Alarm
54 = Fire Zone Reset
36 = **At Siren Timeout***
58 = Duress
38 = Chime
60 = AAV
39 = Any Fire Alarm
66 = Function Key†
40 = Bypassing
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
Any partition
0
Press [∗] to continue and skip to the "Output Action" prompt.
Press 1 to delete this
output definition.
0 = restore; 1 = alarm;
2 = fault; 3= trouble
15 = Medical
16 = Fire w/verification
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
82 = Blockschloss
90-93 = Configurable
68 = Telecom Line Cut
69 = Telecom Line Restore
70 = AC Mains Restore**
71 = System Startup/Clock Not
Set
72 = Clock Set
78 = Keyswitch Red LED
79 = Keyswitch Green LED
80 = Tamper Fault
0 = any partition; 1 = partition 1;
2 = partition 2; 3 = partition 3
5-11