11.0 Fitting the Outer Case – page 25
Fig. 37
Fig. 38
11.1

Fitting The Outer Case

1.
Position the outercase over the boiler engaging the lugs
in the side flanges over the hooks on the wall plate (Fig.
37).
2.
Using the two screws supplied in the kit, secure the
outercase to the combustion box (Fig. 37).
3.
Replace the lower front door panel (Fig. 38).
4.
Carefully read and complete all sections of the
"Benchmark" Installation, Commissioning and Service
Record Log Book that are relevant to the appliance and
installation. The details of the Log Book will be required
in the event of any warranty work. The Log Book must
be handed to the user for safe keeping and each
subsequent regular service visit recorded.
5.
Instruct the user in the operation of the boiler controls.
Hand over the User's Operating, Installation and
Servicing Instructions and the Log Book, giving advice
on the necessity of regular servicing.
6.
Advise the user that a plume of vapour from the flue
terminal is normal, and that there is no need for
concern.
IMPORTANT: This boiler is fitted with an aluminium alloy
heat exchanger. It is important that the system is thoroughly
flushed in accordance with BS 7593 and that one of the
following inhibitors is used:
BETZ DEARBORN SENTINEL X100
FERNOX COPAL
Refer to inhibitor manufacturer's instructions for correct
use. Failure to comply with this requirement will invalidate
the appliance warranty.
It is also important to check the inhibitor concentration after
installation, system modification and at every service.
Date Boiler Installed ......./......./.........
Inhibitor Used ....................................
7.
This label is located on the electrical box front cover on
the boiler. Detail of system treatment should be added
for future reference.