Baxi Barcelona Installation And Servicing Instructions page 20

Wall mounted powered flue condensing boiler gas fired central heating unit
Hide thumbs Also See for Barcelona:
Table of Contents

Advertisement

8.0
Installation – page 20
Fig 28
8.7
Fitting the Flue (Cont)
6.
Ensure the inner flue support bracket is positioned in
the flue (Fig. 28).
7.
Engage the flue into the flue elbow using soap solution
to ease the engagement ensuring the flue is assembled
as shown (Fig. 29).
8.
Place the gasket over the flue exit on the boiler.
9.
Slide the flue assembly through the hole in the wall.
10. Engage the elbow on to the flue connection on top of
the boiler. Secure with the four screws supplied in the
kit.
11. Make good between the wall and air duct outside the
building ensuring the 3º drop between the terminal and
elbow.
12. The flue trim should be fitted once the installation is
complete and the flue secure (Fig. 30). Apply a suitable
mastic to the inside of the trim and press against the
wall finish, making sure the brickwork is dust free and
dry.
13. If necessary fit a terminal guard (see Section 7.11).
VERTICAL FLUEING
1.
Only a flue approved with the Baxi Barcelona can be
used.
2.
For information on vertical flues consult the Baxi Gas
Central Heating Boilers Installer Guide or Notes for
Guidance supplied with the vertical flue pack.