Electronic settings.
Fig.G.20: Electronic adjustment.
Setting possibilities:
BR1 (1): this can be used to eliminate the pump bypass time of 20 seconds.
- With jumper: bypass time active
- Without jumper:
BR2 (2): this can be used to activate the optional flame probe.
- Jumper on 1/2:
- Jumper on 2/3:
X5 (3): the data logger is connected here for readout of operating data. X5 is also im-
portant for setting the service interval.
Service interval settings:
Switch off the machine with S1. Place a wire jumper (9) between pins 3 and 5 on X5.
Switch on the machine ("Cold water" mode). By temperature setting it is now possible
to set a new service interval, read from the status display LEDs (4-8): beginning with
the "Fuel" LED (4), each LED stands for 100 h, producing a setting range of 100 to 500
h in 100 h increments. If the setting is not altered for 3 s, the value is assumed, indica-
ted by flashing of the set LEDs. The machine must then be switched off by S1, and the
wire jumper removed from X5. The default ex works is 200 h.
NEPTUNE 4 FA_EN_Ver.2.0_ 22/11
Adjustment / Test
bypass time eliminated
flame probe inactive
flame probe active
1)
BR1
2)
BR2
3)
X5
4)
Fuel LED
5)
Anti Scale LED
6)
Service LED
7)
Pump oil LED
8)
Operation LED
9)
Service jumper
301001873
G
52