(to EC Directive 2006/95, 2004/108, 99/5) DECLARATION OF CONFORMITY With the present declaration, we certify that the following products : INTEK HR-5500 comply with all the technical regulations applicable to the above mentioned products in accordance with the EC Directives 2006/95/EC, 2004/108/EC, 99/5/EC.
With a correct use of the product in accordance with the operating method described in this manual, the product will offer a trouble free use for many years. INTEK is constantly engaged to develop and provide quality products meeting the customers requirements, however any suggestion or comments on this product that might help us to improve quality are warmly welcome.
Functions and Features FUNCTIONS AND FEATURES WARNING Big LCD which displays frequency and all kinds of information To use the radio, please connect the antenna to the location "B" on DUAL-DIGITAL TUBE FOR CHANNEL DISPLAY the back panel of the equipment firstly and then set the SWR USE EL technology for backlight (Standing Wave Ratio) before transmitting.
A fixed antenna should be installed in a space as clear as possible. If it is fixed to a mast, it will perhaps be necessary to stay it, according to the laws in force (you should seek professional advice). All HR-5500 antennas and accessories are designed to give maximum efficiency to each radio within the range.
Page 7
Installation 3. POWER CONNECTION 4. BASIC OPERATIONS TO BE CARRIED OUT BEFORE USING YOUR Your RADIO is protected against an inversion of polarities. However, before SET FOR FIRST TIME (without transmitting or using the <<Push-To- switching it on, you are advised to check all the connections. Your equipment Talk>>...
Installation - Controls and Operation 6. HOW TO USE INTERNAL SWR METER 10K : Appears when +10KHZ function is started. - Set to channel 20@D band in FM. EMG : Appears when EMG channel is used. - Press <<push-to-talk>> button on the microphone to transmit. SWR : Appears when SWR is used.
Controls and Operation it is desired that the control be adjusted only to the point where the receiver Amplitude Modulation/AM : Communication on a field with relief and background noise or ambient background noise is eliminated. Turn fully obstacles in middle distance (the most used). anticlockwise then slowly clockwise until the receiver noise disappears.
Page 10
Controls and Operation Release FUNC key, and then press other keys to realize the second To enable the DW function, firstly turn the SQ control clockwise until the functions silk-screened under the button. "FUNC+ Keypad name" is to be background noise is cut out. Select the first channel to be monitored by used in the following operating instruction.
Page 11
Controls and Operation To exit the SCAN function, press the SCAN key or the PTT key. (2) FUNC+ SWR The Scan Type above is the SQ mode under SCA Selection in Function When pressing this key, TOT ON or TOT OFF would display on the LCD for Menu.
Page 12
Controls and Operation - Function Menu Setup 24. EXT SP or PA SP 1. PTT EXT SP Transmitting key, Press to speak and release to receive a message. Accept 4 to 8 ohm, 4 watt external speaker to be connected. When external 2.
Function Menu Setup (1) STP (Frequency Tuning Step) COA : When this option is selected, press PUSH and turn CLARIFIER knob to realize COARSE function. When pressing this key, "2" icon will appear on far left of the LCD. Under this condition, rotate the CLARIFIER knob to change This menu is to set tuning step when adjusting frequency by CLARIFIER knob frequency of both transmitting and receiving.
Page 14
Function Menu Setup (6) SC Scanning Type Selection This menu is to choose whether to enable Power supplied Voltage Protection function or not. ON : When ON is selected, the radio will detect the supplied voltage. Once the voltage surpasses the voltage setup in advance, the radio would This menu is to set Scan Type.
Page 15
Function Menu Setup This menu is to select frequency of Roger Beep. The frequency range is (16) ICG 300KHz - 3KHz. The shift step is 10Hz. This menu refers to MIC GAIN function. Users Default : 1050Hz can set the value by software. The higher value goes to higher sensitivity.
Specifications GENERAL RECEIVER Frequency 28.000 - 29.700 MHz (25.615 - 30.105 MHz) (*) Sensitivity (12dB Sinad) SSB : 0.25µV for 10dB (S+N)/N at greater Frequency Bands A/B/C/D/E/F than 1/2W of audio output Channels 60 Channels (programmable) in each band AM : 1.0µV for 10 dB (S+N)/N at greater Frequency Control Phase-Locked-Loop Synthesizer than 1/2W of audio output...
Optional Accessories - User Information OPTIONAL ACCESSORIES D-056 USB type PC interface cable USER INFORMATION in accordance with art. 13 of the Legislative Decree of 25th July 2005, no. 15 ”Implementation of Directives 2002/95/EC, 2002/96/EC and 2003/108/EC, relative to reduction of the use of hazardous substances in electrical and electronic equipment, in addition to waste disposal”. The crossed bin symbol shown on the equipment indicates that at the end of its working life the product must be collected separately from other waste.
Need help?
Do you have a question about the HR-5500 and is the answer not in the manual?
Questions and answers