Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
Matrix
Control Panel Assembly
Matrix
Control Panel Assembly
18
!
WARNING
Test Procedure
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad
1000 – 15000 Ω for All other pads
16
9
8
1
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad
1000 – 15000 Ω for All other pads
16
9
8
1
16022498 Rev. 0
Results
Pad
Trace
Measurement
1
13 & 15
Continuity
2
12 & 15
Continuity
3
10 & 15
Continuity
4
7 & 13
Continuity
5
12 & 13
Continuity
6
10 & 12
Continuity
7
4 & 13
Continuity
8
4 & 12
Continuity
9
4 & 10
Continuity
0
5 & 12
Continuity
Cancel
1 & 2
Continuity
Clock
5 & 14
Continuity
Cook & Hold
15 & 14
Continuity
Broil
4 & 5
Continuity
Bake
7 & 15
Continuity
Clean
13 & 14
Continuity
Keep Warm
7 & 14
Continuity
Favorites
5 & 13
Continuity
Timer
4 & 14
Continuity
Light
12 & 11
Continuity
Pad
Trace
Measurement
1
5 & 14
Continuity
2
4 & 14
Continuity
3
4 & 13
Continuity
4
4 & 12
Continuity
5
4 & 10
Continuity
6
13 & 14
Continuity
7
4 & 5
Continuity
8
5 & 13
Continuity
9
5 & 12
Continuity
0
5 & 10
Continuity
Cancel
1 & 2
Continuity
Clock
13 & 15
Continuity
Cook & Hold
12 & 11
Continuity
Broil
7 & 15
Continuity
Bake
7 & 14
Continuity
Convect
10 & 11
Continuity
Clean
10 & 12
Continuity
Keep Warm
4 & 7
Continuity
Favorites
10 & 15
Continuity
Timer
12 & 13
Continuity
Light
12 & 15
Continuity