INSTALLATION, OPERATING
& SERVICE INSTRUCTIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED
BY PROFESSIONAL PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PLUMBER OR GAS FITTER. APPROVAL NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be
obtained by consulting your local gas supplier.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,
adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided
with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified
or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer
to the Garland web site at http://www.garland-group.com. The information contained herein, (including design and parts
specifications), may be superseded and is subject to change without notice.
Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice.
GARLAND COMMERCIAL INDUSTRIES
85 East South Street
Freeland, Pennsylvania 8224
Phone: (570) 636-000
Fax: (570) 636-3903
Part # 9229077 (07/05)
Part # 9229077 (07/05)
FOR THE
"GX" SERIES
CHAR-BROILERS
GARLAND COMMERCIAL RANGES,
LTD.
77 Kamato Road, Mississauga, Ontario L4W X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
Enodis UK LTD.
Swallowfield Way, Hayes, Middlesex UB3 DQ ENGLAND
Telephone: 08-56-0433
Fax: 08-848-004
© 2005 Garland Commercial Industries, Inc.
Page 

Advertisement

Table of Contents
loading

Summary of Contents for Garland GXC24

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,...
  • Page 2 Page 2 Part # 9229077 (07/05)
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Dimensions And Specifications ........4 Introduction .
  • Page 4: Dimensions And Specifications

    3/4"N.P.T.[19mm] REARGASINLET • Many local codes exist, and it is the responsibility of the owner and the installer to comply with these codes .• Garland reserves the right to change or improve our, specifications without notification. 31-3/8" 27” • These appliances are intended for commercial use by...
  • Page 5 DIMENSIONS AND SPECIFICATIONS Continued NATURAL GAS L.P. GAS MODEL NUMBER Orifice Size Input=BTU/HR Orifice Size Input=BTU/HR GXC24 2 @ 45,000 2 @ 45,000 GXC30 2 @ 45,000 2 @ 45,000 GXC36 3 @ 45,000 3 @ 45,000 GXC48 4 @ 45,000...
  • Page 6: Introduction

    INTRODUCTION Garland manufactures the GX Series Char-Broilers with Rating Plate two different types of radiants, with widths ranging from The rating plate is attached to the Char-broiler’s body on 24” to five feet. While service and customer operation the left hand inside wall at the lower front. It is accessible may vary from model to model, installation is similar after opening the front apron door.
  • Page 7: Positioning And Setup

    This tape must be removed prior to lighting Garland Char-Broilers use a ¾” NPT inlet. Sealant on the pilots. Once free, double-check that the burners are all pipe joints must be resistive to LP gas...
  • Page 8: Rigid Connections

    Flexible Couplings & Connectors These adjustments are the responsibility of the customer, If the unit is to be installed with flexible couplings installer and/or dealer and are not covered by the Garland and/or quick-disconnect fittings, for an appliance warranty. equipped with casters, the installation shall be made All burners are equipped with constant-burning pilots.
  • Page 9: Initial Pilot Light

    Cooking equipment . Remove the broiler grates. Wire brush them clean is no exception. Your Garland Char-Broiler must be kept of any encrusted materials and wash in hot, soapy clean during the working day and thoroughly cleaned water.
  • Page 10: Daily-Gxr Series

    If it is necessary to scrape stainless steel radiants. to remove encrusted materials, soak the encrusted area 3. The Garland Char-Broiler uses a double drip tray. with wet cloths to loosen the material, then use a wood The front grease trough (at the top of the unit) or nylon scraper.
  • Page 11 NOTES Part # 9229077 (07/05) Page ...