Stove Stops Feeding Pellets And Shows Warning Code "H; Stove Stops Feeding Pellets And Shows Warning Code "D - Enerzone BIO-35 Owner's Manual

Freestanding & fireplace insert
Table of Contents

Advertisement

STOVE STOPS FEEDING PELLETS AND SHOWS
WARNING CODE "H"
Possible Causes:
1.
One of the two L-250 automatic high temperature switches has been
tripped.
CODE
BEFORE RESETING
H1, H2, H3
Heat exchanger and/or exhaust system
OR H4
is/are clogged. Refer to the owner's manual
for maintenance procedures.
*** After 3 attempts, reset is no longer possible. Call SBI technical support.
STOVE STOPS FEEDING PELLETS AND SHOWS
WARNING CODE "d"
Possible Causes:
1.
The hopper lid has stayed open for more than 3 minutes
THE STOVE IS RUNNING BUT DISPLAYS WARNING CODE
Possibles Causes:
Warning generated by a power failure while the stove was
running.
Possible Remedies:
The L-250 automatic high temperature switches are located on the top and
bottom of the auger housing They send a signal to the control board if the
auger housing overheats.
INSPECT YOUR UNIT. Improper installation, poor maintenance, or a
defective or missing component may be causing the stove to overheat.
Reset the stove and restart it. Call a technician if you get this code again.
*See procedure below to restart the stove.
TO RESET
Press simultaneously for 2 seconds
icons .
Possible Remedies:
As a security measure, the auger will stop turning and feeding pellets as
soon as the hopper lid opens. It will resume normal operation as soon as
the hopper lid is closed. However, if the hopper lid stays open for more
than 3 minutes, the unit will stop and a code "d" will appear on the control
board. Close the hopper lid. Reset the unit and start it again.
Possibles Solutions:
The stove will restart on the initial setting once it cools off.
Note: For a short power failure (less than 5 seconds), the stove will continue to
function at the selected speed.