Advanced RF communication check
!
To save power the battery
devices only communicate
with the Central Controller
every four minutes therefore
the system may not
respond immediately to a
manual change.
Step 4: System test
To check the RF signal strength between the wireless devices
and the Central Controller go to RF COMMS CHECK in the
Central Controller Installer Menu and test each wireless device.
On the Central Controller press and
1
hold 'Settings' for 3 seconds
Press the green tick
2
Press RF COMMS CHECK
3
Choose the devices you want to test
4
Mains Powered Wireless Devices
Mains powered devices do not need to be put into
test mode and will automatically respond to the
test message sent from the Central Controller:
Wireless Relay Box (BDR91)
• The Relay Box will flash the green LED from 1 flash (poor)
to 5 flashes (excellent) – no flashing means the Relay Box
has not received a test signal from the Central Controller
Remote Access Gateway (RFG100)
• The Gateway will flash the green LED from 1 flash (poor)
to 5 flashes (excellent) – no flashing means the Gateway
has not received a test signal from the Central Controller
Underfloor Heating Controller (HCE80/HCC80)
• The Underfloor Heating Controller will flash the
green LED for the zone you are testing from 1
flash (poor) to 5 flashes (excellent) – no flashing
means the Underfloor Heating Controller has not
received a test signal from the Central Controller