2. Installing Switch
[Step 2] Attaching a wrist strap
Attach an antistatic wrist strap to the wrist strap terminal.
NOTE
[Step 3] Connecting the operation terminal
1.
Connect the operation terminal to the CONSOLE port. Use an RS-232C
crossover cable for the connection.
2.
Start the operation terminal.
3.
Start the communication software.
NOTE
[Step 4] Connecting the interface cable
Connect the interface cable to the interface port.
[Step 5] Turning on the power
Set all power switches of the Switch (with an AC power supply unit installed) or the
circuit breaker (with a DC power supply unit installed) to ON.
NOTE
14
The terminal for an antistatic wrist strap on the Switch supports 4 mm banana
plugs. Use a 4 mm banana plug for the wrist strap terminal.
For details about how to configure the communication software, see the
documentation for the communication software.
Set all power switches or circuit breakers to ON within five seconds of turning
the first switch or circuit breaker on. If you take longer than five seconds, the
management and switching unit detects a power failure, and failure information
is displayed on the LCD display. If this happens, take action as described in the
following table.
Display on the LCD display
E8 PS Msg=00000001
[MD] FAULT 2200
220000aa00bb
The values for aa and bb above vary depending on the installation status of the
power supply unit and the status of the power supply.
Action
The Switch is ready. Set all power switches or
circuit breakers to ON.
(When the power failure is resolved, the
display on the LCD display disappears.)
The Switch is unable to start operation
because the power supply capacity is
insufficient.
Set all power switches or circuit breakers to
OFF, and then set them to ON again.