Data And Dimensions - eta SH Installation Manual

Log boiler 20-60 kw
Table of Contents

Advertisement

Data and dimensions

SH 20-30 kW (40-60 kW)
Cleaning lever and actuators can be mounted
left or right sided
a Flow R5/4" female
b Return R5/4" female
c Drain R1/2" female
d Safety heat exchanger R1/2" male
Wood gasification boiler SH
Rated capacity
Beech log efficiency, partial/full load*
Fuel chamber
Fuel chamber volume
Beech log combustion period, partial/full load*
Dimensions without housing, W x D x H
Weight
Water content
Waterside resistance (ΔT = 20 °C)
Flue gas mass flow rate, partial/full load
CO2-content in dry flue gas, partial/full load*
Exhaust temperature, partial/full load*
Flue draught
Carbon monoxide (CO) emission
Partial/full load*
Dust emissions
full load*
Unburned hydrocarbon emissions
(CxHy) Partial/full load*
Electrical power consumption
Partial/full load*
Recommended buffer storage tank volume
Maximum permissible operating pressure
Temperature adjustment range
Maximum permissible operating temperature
Minimum return temperature
Conforms to
BLT Wieselburg
EU standards
Austria
6
>300
1102 (1180)
Ø150
Litres
Litres
mg/MJ
mg/m³ 13%O2
mg/MJ
mg/m³ 13%O2
mg/MJ
mg/m³ 13%O2
W
Litres
3 bar
Boiler rating
70 – 85°C
Suitable fuels
95°C
Electrical connection
60°C
*Data from test reports of BLT Wieselburg, log numbers 041/10, 028/99 and 007/00.
The test reports of BLT Wieselburg can be found on the Internet at: blt.josephinum.at
TÜV
Quality seal of
South Germany
Holzenergie Schweiz
>800
20
30
kW
10 - 20
15 - 30
%
95,4 / 92,9
92,7 / 89,3
mm
560 mm deep for 0,5 m logs, 340 x 365 mm door opening
150
h
19,2 / 8,6
12,1 / 6,3
mm
588 x 940 x 1.495
kg
580
583
110
Pa /
190 /
370 /
mWs
0,019
0,037
g / s
7,0 / 12,8
10,4 / 18,6
%
12 / 14
12 / 14
°C
100 / 130
100 / 140
2 Pa for partial load / 5 Pa for full load required
over 30 Pa draught limiter required
153 / 145
43 / 94
241 / 229
65 / 143
10
7
15
10
2 / 3
19 / 7
3 / 4
25 / 10
69
86
> 1.100, opt. 2.000
Austrian
Listed on the Energy
ecolabel
Technology List
www.eta.co.at
>200
613 (716)
>800
263
(362)
a
d
c
b
410 (510)
106
40
50
20 - 40
20 - 49,9
20 - 60
93,6 / 91,4
93,6 / 91,4
93,6 / 91,4
223
14,1 / 7,1
14,1 / 5,6
14,1 / 4,7
688 x 1.015 x 1.675
791
793
170
220 /
340 /
0,022
0,034
12,2 / 24,0
12,2 / 30,2
12,2 / 35,4
14 / 14,5
14 / 14,5
90 / 145
90 / 150
90 / 160
120 / 30
182 / 46
10
15
2 / < 1
3 / < 1
87
> 2.200, opt. 3.000
5 according EN 303-5:2012
Spruce and beech up to W20
1 x 230 V / 50 Hz / 13 A
The Certification Mark for Onsite
Sustainable Energy Technologies
60
795
480 /
0,048
14 / 15

Advertisement

Table of Contents
loading

Table of Contents