Rear wall insulation, door frame

Attach angle bracket to rear wall insulation
Fasten the angle bracket to the rear wall insulation
with 3 self-tapping 3.5 x 9.5 screws.
Attach rear wall insulation to boiler
Press the rear wall insulation onto the rear side of
the boiler.
Install door frame
Attach the door frame to the front of the boiler
with 4 M5 X 10 round-headed screws.
Break out openings for air valve shafts from side
panel
Take the side panel for the side on which the actu-
ators are to be mounted.
Use a screwdriver to break out both openings for
the air valve shafts from this side panel.
32
www.eta.co.at
Installation
Angle bracket