VKI Technologies Eccellenza touch Operation Manual page 81

Hide thumbs Also See for Eccellenza touch:
Table of Contents

Advertisement

Message Displayed
Powder Dispensers current is under
minimum operation level
Powder Dispensers Over Current
StandBy
Powder Whippers Over Current
StandBy
The water level is reaching the
safety level probes
Valves & Relay current is over
safety level.
Valves & Relay current is under
minimum operation level
Water Tank Coil Valves
Over Current StandBy
Water Tank Default
Critical Min Temp
Water Tank Default Fill
Heating Time
Water Tank Detectors
Power Failure
Water Tank Heater
Over Current StandBy
Water Tank Heating
Timeout
Water Tank Heating Probe
Error
Water Tank Level Error
Water Tank Temperature
Probe Short
Water Tank Temperature
Probe Not Present
VKI Publication #100308-003
Code
Condition
M1,
Powder Dispenser current is below
M2,
the minimum operating level.
M3
The powder dispensers current sum
Z99
was over the configured stand by
operation level.
Powder whippers current sum was
Z99
over the configured stand by
operation level
The water tank has overfilled and
L5
the water level is reaching the safety
level probe.
Valves & Relay current has exceeded
V1-V6
the maximum operating level.
Valves & Relay current is below the
V1-V6
minimum operating level.
Valve(s) current has exceeded the
Z99
configured stand by operation level.
Water temperature went below the
H1
configured minimum critical
temperature (Default 0 C).
Inlet valve and heater were both
H1
activated for a period of time longer
than the configured timeout.
Fault signal triggered due to a failure
Z99
of the level probes and overflow
detector power supply.
Heater current has exceeded the
Z99
configured stand by operation level.
Reaching the water set point
(Default 95 C) took longer than the
H1
maximum configured heating
timeout (Default: 30 min.)
Heater bad connection count has
H1
exceeded the configured limit.
Safety level probe is detected while
L4
the normal level probe is not.
T1 Temperature probe is shorted
T1 Temp probe is open.
Eccellenza Touch
Action(s) Required
1 - Check the wiring and connections
to the powder dispenser motor.
2 - If message persists, replace the
powder dispenser motor.
1 - Clear the message.
2 - Reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
1 - If this occurs during initial
heating, it may be due to water
expansion. Empty some water from
tank.
2 - The machine may have been
moved causing tank to overfill.
Empty some water from tank.
3 - Level probes require cleaning.
1 - Clear the message.
2 - If message persists, the inlet
valve or one of the outlet valves
may need to be replaced.
1 - Clear the message.
2 - Check wiring and connections to
inlet and outlet valves.
3 - If message persists, the inlet
valve or one of the outlet valves
may need to be replaced.
1 - Clears automatically. If not,
reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
3 - If message persists, replace the
control board.
1 - Clears automatically. If not,
reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
3 - If message persists, replace the
heater element.
1 - Clear the message.
2 - Reboot the machine.
1 - Check wiring and connections to
the level probes.
2 - Clean level probes.
1 - Check the wiring and connection
to the temperature probe.
2 - Replace the temperature probe.
1 - Check the wiring and connection
to the temperature probe.
2 - Replace the temperature probe.
81