Message Displayed
Coffee Dispensers current is over
safety level
Coffee Dispensers current is under
minimum operation level
Coffee Dispensers Over Current
Standby
Coffee Grinder Over Current Standby
CUP LIGHT LED #1 is not detected/
CUP LIGHT LED #2 is not detected
Fan is not present or has abnormal
operation
Grinder Fuse Fault
Grinder Sensor Error
Grinder's current is close to critical
level
Grinder's current is close to minimum
operation level
Grinder's current is over safety level
Grinder's current is under minimum
operation level
VKI Publication #100308-003
Code
Condition
Coffee dispenser motor current has
M6,
exceeded the maximum operating
M7
level.
M6,
Coffee dispenser motor current is
M7
below the minimum operating level.
The coffee dispensers current sum
Z99
was over the configured stand by
operation level.
The grinder current was over the
G1
stand by operation level.
S1, S2 Cup Light LED #1 or #2 is shorted.
Fan is not present or operating
K1
abnormally.
G1 Grinder fuse is in fault.
G1 Grinder Current Sensor is out of range.
Grinder current is close to maximum
G1
operating level. Grinder may be
drawing too much power.
Grinder current is close to minimum
G1
operating level. Grinder may not be
drawing enough power.
Grinder current has exceeded the
G1
maximum operating level.
Grinder current is below the
G1
minimum operating level.
Eccellenza Touch
Action(s) Required
1 - Check to see if the coffee
dispenser motor is jammed.
2 - Reboot the machine.
3 - If message persists, replace the
coffee dispenser motor.
1 - Check the wiring and connections
to the coffee dispenser motor.
2 - The coffee dispenser may not be
engaged with the dispenser motor.
3 - The coffee dispenser motor
coupling may need to be replaced.
4 - If message persists, replace the
coffee dispenser motor.
1 - Clear the message.
2 - Reboot the machine.
1 - Clear the message.
2 - Reboot the machine.
1 - Replace LED/harness.
1 - Check fan wiring and connection
to the control board.
2 - Clean any accumulation from fan.
3 - If message persists, replace the
exhaust fan.
4 - If message persists, replace the
control board.
1 - This message resets
automatically after all critical errors
have been fixed.
1 - Clear the message.
2 - Reboot the machine.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
1 - Reboot the machine.
2 - If message persists, replace the
grinder.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
1 - Check the condition of the
grinder belt.
2 - Check the wiring and connections
to the grinder.
3 - The grinder may need to be
replaced.