2. From the set administration menu, scroll up/down to display IP parameters and press OK
3. Scroll up/down to display and configure the download parameters of the set binary and
configuration files (Alcatel-Lucent OmniPCX Office Communication Server server) :
DL Scheme: press several times the OK button to specify the transfer mode: HTTPS
Use Default Port: click the OK button to confirm that the default port value (443) is
retained for HTTPS
DL Addr: press the OK button and enter IP address of the Alcatel-Lucent OmniPCX
Office Communication Server server
DL Port: parameter not used
DL Path: press the OK button and enter the access path where the set binary and
configuration files are located (/dmcfg/)
4. After the DL Path parameter, scroll up/down to display Save and press OK
Configuring the user name and password in OMC
To modify the name and reset the password:
-
In OMC, go to Users/Base stations List.
-
Click the user in the list, modify her/his name in the corresponding field and click Modify.
-
In the SIP Parameters tab, click the SIP password reset button to get a new password (In
OMC, only reset of user password can be done, user password can be set only in
8002/8012 Deskphone set).
Connecting optional equipment
Headsets
A wired headset can be used with 8012 Deskphone sets.
By default the set is configured to detect headset connection. When the headset is plugged
into the 3.5 jack connector, the audio is sent to the headset. The hands-free key allows you to
switch from handset to headset.
Rebooting an 8002/8012 Deskphone set
To reboot a set:
1. In OMC, go to Users/Base stations List > Details.
2. Click Reset button.
The Reset window opens.
3. Select Reboot and click OK.
4. In the confirmation window, click Yes.
Displaying SIP Connection Current Status
This feature allows the display of SIP connection status.
To display SIP connection status:
1. In OMC, go to Users/Base stations List > Details.
2. Read the SIP connection status (under the terminal's physical status).