The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.
Preface This preface provides general information about the documentation set for the 7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network terminals (ONTs). Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release.
For ordering information, contact your Alcatel-Lucent sales representative. Alcatel-Lucent quality processes Alcatel-Lucent’s 7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network terminals (ONTs) manufacturing, testing, and inspecting practices are in compliance with GR-1252-CORE and TL 9000 requirements. These requirements are documented in the Operations Quality Plan 8BD000234204QRZZA and the Alcatel-Lucent North American Quality Manual 8BD000010000QRZZA.
Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA...
Click on the Search button. Acrobat Reader displays the search results. You can expand the entries for each document by clicking on the + symbol. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
7342 ISAM FTTU ONT customer documentation and on the equipment. Safety instruction boxes The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer documentation. Observe the instructions to meet safety requirements. The following is an example of the Danger box.
Note — Information of special interest. The Note box provides information that assists the personnel working with 7342 ISAM FTTU ONTs. It does not provide safety-related instructions. Safety-related labels The ONT equipment is labeled with specific safety compliance information and instructions that are related to a variant of the ONT.
Page 9
CAUTION This Assembly Contains Electrostatic Sensitive Devices 18533 Safety standards compliance This section describes the ONT compliance with North American safety standards. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
U.S. standards. Power supplies The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support contract with Alcatel-Lucent. Such use greatly increases the danger of damage to equipment or property.
For Class 1 laser products, lasers are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Figure shows a sample laser product safety label on the ONT equipment. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xiii 3FE 51892 AAAA TCZZA...
When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
7342 ISAM FTTU ONT customer documentation and on the equipment. Safety instruction boxes The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer documentation. Observe the instructions to meet safety requirements. The following is an example of the Danger box.
Note — Information of special interest. The Note box provides information that assists the personnel working with 7342 ISAM FTTU ONTs. It does not provide safety-related instructions. Safety-related labels The ONT equipment is labeled with the specific safety instructions and compliance information that is related to a variant of the ONT.
Page 17
ETSI ONT safety guidelines Figure 6 CE declaration of conformity on the ONT equipment No1013 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xvii 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The ONT equipment complies with EN 300 753 acoustic noise emission limit and test methods. Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. xviii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The ONTs comply with BS EN 61140. Power supplies The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support contract with Alcatel-Lucent. Such use greatly increases the danger of damage to equipment or property.
Figure 7 Laser product label 18455 Figure shows a laser classification label. Laser classification labels may be provided in other languages. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 21
• wavelength • normal output power • maximum output power Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Danger — Risk of eye damage by laser radiation. Location class Use cable supports and guides to protect the receptacles from strain. xxii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
• When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxiii 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 24
ETSI ONT safety guidelines xxiv July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the 7342 ISAM FTTU packet optical line termination (P-OLT) and Optical Network Termination (ONT) systems. This chapter also includes environmental operation parameters of general interest.
Page 26
Products). The number contained inside the label indicates the Environment-Friendly User Period (EFUP) value. The label may be found in this documentation or on the product. xxvi July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
18985 Together with major international telecommunications equipment companies, Alcatel-Lucent has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and EFUP of 20 years for handsets and accessories. These values are based on manufacturers' extensive practical experience...
This Directive applies to electrical and electronic products placed on the EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment. Alcatel-Lucent products shipped to the EU after 1 July 2006 comply with the EU RoHS Directive.
Page 29
Moreover, in compliance with legal requirements and contractual agreements, where applicable, Alcatel-Lucent will offer to provide for the collection and treatment of Alcatel-Lucent products bearing the logo at the end of their useful life, or products displaced by Alcatel-Lucent equipment offers. For information regarding take-back...
Page 30
ETSI environmental and CRoHS guidelines July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Equipment safety standard compliance ..........x Environmental standards compliance ..........x Laser product standards compliance ..........x Resistibility requirements compliance ..........x Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxxi 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 32
Other environmental requirements ..............xxvii ONT environmental requirements ..........xxviii Storage................xxviii Transportation ..............xxviii Stationary use ..............xxviii Thermal limitations ..............xxviii xxxii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 33
ONT activation methods ............... 4-4 SLID entry via craft terminal ............4-4 SLID entry via Ethernet port............4-5 SLID entry via first POTS port ............4-5 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxxiii 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 34
Alexandria FPGA..............6-7 VDSL2 subsystem ..............6-7 Voice subsystem ..............6-8 Ethernet subsystem ..............6-9 RF video amplifier ..............6-9 SWRD .................. 6-10 xxxiv July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 35
3EM 17661 AC compartment............7-41 3EM 20293 AA compartment............7-42 7.11 Location options................ 7-44 8 — UPS LEDs Overview ................. 8-2 UPS LEDs.................. 8-2 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxxv 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 36
Indoor ONT (I-240G-A and I-241G-A) ........... 10-26 Indoor ONT (I-220E-A and I-221E-A) ..........10-26 Indoor ONT (in-wall MoCA)............10-27 Indoor ONT (I-211M-D)............10-27 xxxvi July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 37
15 — I-020G-F unit data sheet 15-1 15.1 Identification ................15-2 15.2 General description..............15-2 15.3 ONT hardware and software features..........15-2 15.4 Special considerations..............15-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxxvii 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 38
Identification ................22-2 22.2 General description..............22-2 22.3 ONT hardware and software features..........22-3 22.4 Special considerations..............22-4 VLAN tagging behavior ............. 22-5 xxxviii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 39
29.4 Special considerations..............29-4 30 — O-24121G-A and O-24120G-A unit data sheet 30-1 30.1 Identification ................30-2 30.2 General description..............30-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xxxix 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 40
Features and application notes ............35-2 35.3 General description..............35-2 35.4 Operating modes ............... 35-3 35.5 Status LEDs ................35-3 35.6 Alarms..................35-4 35.7 Connections ................35-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 41
Features and application notes ............39-2 39.3 General description..............39-2 39.4 Status LEDs ................39-2 39.5 Alarms..................39-3 39.6 Connections ................39-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 42
43 — PowerShield CP50B48 UPS unit data sheet 43-1 43.1 Identification ................43-2 43.2 Features and application notes ............43-2 43.3 General description..............43-3 xlii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 43
Alarms..................43-4 43.7 Connections ................43-4 43.8 Specifications ................43-5 Physical description..............43-6 Power ................. 43-6 Environmental ............... 43-6 Glossary Index Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xliii 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 45
Figure 40-3 BBU output power and alarm connector ......... 40-7 Figure 41-1 Delta DUPS-1232A LEDs and user control button ....... 41-4 Figure 41-2 Delta DUPS-1232A UPS output power and alarm connector ....41-6 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA...
Page 46
Table 6-15 GE multilayer switch features............6-15 Table 6-16 OBC functions................6-16 Table 6-17 OBC interfaces................. 6-18 Table 7-1 ONT connection capacity............... 7-2 xlvi July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 47
Table 9-17 Indoor ONT RJ-45 LEDs (I-221E-A, I-220E-A, I-020G-F, I-020G-G, I-211M-D, I-211M-E, I-241G-A, I-240G-A, and I-040G-A) ....9-16 Table 9-18 Indoor ONT RJ-45 LEDs (I-020E-B and I-020E-H) ........9-17 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 xlvii 3FE 51892 AAAA TCZZA...
Page 48
Table 10-39 O-821M-E measured power consumption........10-29 Table 10-40 MoCA SOHO outdoor ONT transmit output power variance ....10-30 Table 10-41 Business ONT power consumption..........10-30 xlviii July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 49
Table 11-3 15-min ONT counters ..............11-9 Table 11-4 Rolling counters ..............11-10 Table 12-1 Overview of unit data sheets for the 7342 ISAM FTTU ......12-2 Table 13-1 Identification of business ONT ............13-2 Table 13-2 ONT hardware features (B-8102-A and B-8112-A)........ 13-3 Table 13-3 ONT management and security features (B-8102-A and B-8112-A)....
Page 50
Table 37-6 CyberShield CS 24 UPS environmental conditions........ 37-6 Table 38-1 Identification of the OPSU/BBU............. 38-2 Table 38-2 LEDs and audible alarms ............. 38-3 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 51
Table 43-1 Identification of the APC UPS ............43-2 Table 43-2 LEDs ..................43-4 Table 43-3 Alarm signal and output levels ............43-4 Table 43-4 UPS output pinouts..............43-5 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 52
Contents July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
7 — ONT equipment layout 8 — UPS LEDs 9 — ONT LEDs 10 — ONT technical specifications 11 — ONT statistics and performance monitoring Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
1 — ONT overview 1.1 About this document 1.2 ONT general description 1.3 ONT product identification 1-10 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
ONT general description The ONT is part of the 7342 ISAM FTTU family of products that provide a “last mile” broadband access solution. The 7342 ISAM FTTU products work seamlessly together to form a fiber access network capable of delivering high quality voice, video, and data services to both single-family and multi-dwelling residential subscribers.
(GPON). ONTs The Alcatel-Lucent ONT products are edge devices that use GPON technology to extend a fiber optic cable from a P-OLT shelf at a CO to a subscriber residence, including single-family residences, multi-dwelling residences such as an apartment building, and small office home office applications.
Page 58
1 — ONT overview The Alcatel-Lucent ONT products provide the following functions and services: • network demarcation for all services • voice interworking function from the analog POTS lines to the VoIP/Ethernet layers • interworking functions between the GEM and Ethernet layers •...
Page 59
(SOHO) applications. The single residence and SOHO outdoor ONTs have environmentally hardened enclosures that you can install outside the subscriber’s premises. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA...
Page 60
CO, outdoor enclosure, or other environmentally-protected area. The LP MDU ONT can also be configured in a small Alcatel-Lucent enclosure for outdoor or indoor deployment. There are two types of LP MDU outdoor ONT: the VDSL LP MDU ONT (O-24121V-A and O-24120V-A) and the GE LP MDU ONT (O-24121G-A and O-24120G-A).
Page 61
(MDU) applications. The MDU ONT supports VDSL2 interfaces that are terminated at the customer’s premises using a VDSL2 modem. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 62
VDSL layer and the Ethernet layer • temperature hardened service plug-in unit Currently, the modular ONT is only available for the ANSI market. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
G984.4, G.983.2 revised compliant OMCI interface for ONT management and provisioning The EMS software system use GUI interfaces to provide element management functions for the OLTs and ONTs. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0 – no RF video interface • E – 10/100 Ethernet • B – the variant Table provides the designation for the modular ONTs. 1-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
1 – one data interface • 0 – no RF video interface • 2 – two DS1/E1 interfaces • A – the variant Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 1-11 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 66
1 — ONT overview 1-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
2.10 ONT Release 3.0 features 2-11 2.11 ONT Release 2.0 features 2-12 2.12 ONT Release 1.0 features 2-13 2.13 ONT initial release features 2-13 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
2 — Feature descriptions Overview This chapter provides a brief description of the features for 7342 ISAM FTTU ONTs. ONT Release 04.05.06 features Table describes the features for ONT Release 04.05.06. Table 2-1 Features for ONT 04.05.06 Feature Description ONT support The following indoor ONTs are supported in this release: •...
Gratuitous ARP discard The ability to enable gratuitous ARP discard on an ONT UNI port basis is provided. The 7342 ISAM FTTU supports a discard mechanism that filters incoming traffic for gratuitous ARP requests. When gratuitous ARP discard is enabled, incoming gratuitous ARP requests are discarded.
• B-8102-A • B-8112-A SIP and H.248 voice software See the ONT Customer Release Notes for more information about softswitch interoperability interoperability. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Analog values for metallic loop tests (MLT) is supported. thresholds DSRL control Provisionable Down stream rate limiting (DSRL) functionality on a per PON basis. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Test commands provide option to “Force” a test even in the presence of a real or suspected subscriber busy condition (2 of 2) ONT Release 04.04.10 features Table describes the features for ONT Release 04.04.10. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Allow users to program overlapping MAC-based multicast addresses with unique IP multicast addresses. ONT Release 04.04.00 features Table describes the features for ONT Release 04.04.00. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
This includes the introduction of additional SIP parameters required to provision these call features. (1 of 2) July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
DTMF tones. This functionality is implemented for both Broadworks Broadsoft and Nortel CS2000 softswitches. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
ONT to provide an extension for LAN traffic, implementing functionality such as VLAN swapping. The physical Microspan equipment is installed in the CO at a location remote to the 7342 ISAM FTTU rack and P-OLT. ONT support The following indoor ONTs are supported in this release: •...
A software activation option (ONTSWACT) has been added to the TL1 command SET-NE-ALL that allows automatic or manual activation of the ONT software following a successful download. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 2-11 3FE 51892 AAAA TCZZA...
VoIP call statistics are gathered for the last incoming or outgoing call on each POTS port that is configured for VoIP on the ONT. You can view these statistics from a management session on the P-OLT. 2-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
It also has a maximum of 1000 ft (304.8 m) loop lengths. Derived VoIP service The 7342 ISAM FTTU provides VoIP that supports G.711 Vocoder. The VoIP supports DSCP and p-bit marking for layer 2 and 3 QoS. The VoIP quality meets MOS of 4 and above.
Page 80
Feature Description GPON optics The 7342 ISAM FTTU supports a 28 dB optical budget between the P-OLT and the ONTs. The 7342 ISAM FTTU provides an optical leveling mechanism during the operation of the P-OLT and ONTs. HSI and 802.1P on ONTs The ONTs support PPP- or DHCP-based data service.
Overview This chapter provides application notes of interest to ONT users. These application notes were first reported in the 7342 ISAM FTTU ONT Customer Release Notes for the ONT release. See the 7342 ISAM FTTU Product Information Manual for application notes of interest for the P-OLT.
SWVERACT and SWVERPSV Troubleshooting Guide • to avoid excessive P-OLT loading, clear all extraneous ONT alarms by setting inactive ONTs out-of-service (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 84
(dying gasp) is only reported from ICS-02 ONT -B variants • IMTE and IMCE Ethernet performance statistics are not supported for ONTs (2 of 2) July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
This chapter provides a functional description of ONT software and security features with reference to ONT hardware functional blocks. Software and security features are developed for each Alcatel-Lucent ONT. The software comes preinstalled in the ONT system memory when the ONT is first delivered.
7342 ISAM FTTU Product Information Manual. This hardware and software architecture supports all the ONT based features described in this chapter and in the 7342 ISAM FTTU Product Information Manual. GPON transmission support The GPON transmission layer supports GEM based packets as well as the following features also described in G.984.3 (GPON TC Layer) ITU specification.
AES is enabled on a per-service level during service configuration using TL1. See the 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI for more information.
NTP servers to derive accurate time settings. If the P-OLT is used to derive time settings, communication is secured using SSHv2. See the 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI for more information.
This tells operators of a problem or disables the ONT so a single rogue ONT cannot affect the entire PON. See the 7342 ISAM FTTU ONT Troubleshooting Guide for more information. Laser stuck on ONTs use watchdog timers to stop errors that cause light to be continuously sent up the fiber.
The 802.1x protocol is only applicable to iBridge mode. In iBridge mode, VLAN-tagged frames are not supported for 802.1x. The 802.1x protocol can be enabled or disabled for each 7342 ISAM FTTU system or for each ONT user-network interface (LAN port).
• opens the port for traffic after successful authentication 802.1x support assumptions The 7342 ISAM FTTU supports 802.1x authentication based on the following assumptions: • Authentication is supported only on LAN ports at the ONT and not for the plain old telephone system (POTS) lines.
An EAP Request Identity message is sent to the port when the re-authentication timer expires. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
ARP cache of a router by sending out a gratuitous ARP request that claims to be the default router. The 7342 ISAM FTTU supports a discard mechanism that filters incoming traffic for gratuitous ARP requests. When gratuitous ARP discard is enabled, incoming gratuitous ARP requests are discarded.
Exclusive mode forwards packets that do not match a configured MAC source address, and drops matching packets. Exclusive mode is used when you want to protect the 7342 ISAM FTTU against virus-infected computers that send traffic using the MAC address of the default router, which is in the computer’s ARP cache table.
Page 96
IP address that is not in the lease table. IP source addresses that are added dynamically through DHCP survive ONT restarts, LT restarts, and NT switchovers. See 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI for configuration information.
5.6 SoC ONTs with four 10/100/1000Base-T Ethernet ports 5.7 SoC ONTs with eight POTS ports 5.8 SoC ONTs with CES DS1/E1 interfaces 5-10 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The SoC technology serves as the main hardware block for all SoC based ONTs; see Figure 5-1. Figure 5-1 SoC hardware block POTS ports Control processor SoC Bridge GPON Ethernet MACs Ethernet ports GPON 19421 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The diplexer interfaces with the GPON MAC on the SoC. Figure shows an ONT with a diplexer, four POTS, and two Ethernet ports. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
RF video amplifier that is enabled or disabled by the SoC control processor. The RF video service is connected to the subscriber equipment using an F-type coaxial connector. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA...
SoC control processor. Figure shows an ONT with one Ethernet port and one MoCA adapter. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Figure shows an ONT with one Ethernet port, as well as one MoCA and RF-optical return adapter. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
G.984.3 compliant multicast using a single GEM port-ID for all video traffic (as mandated by G.984.3) • up to of 64 video multicast streams per ONT • IPoE and PPPoE packets July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Figure 5-8 SoC with external DSP for SOHO and BONT ONTs Power Converter External RJ-11 POTS (8) GPON Triplexer RJ-45 Ethernet (2) F-type Video amplifier coaxial 19420 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Ethernet link. These services are carried across the Ethernet network. The network aggregates the traffic, both Ethernet and PON. The CES traffic is transmitted across a CES VLAN that is created between the 7342 ISAM FTTU and the 7450 ESS.
Page 107
NTP servers with a provisionable security key. During a loss of service (LOS) state on the GPON interface, a minimum 32 ppm clock is maintained. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 5-11 3FE 51892 AAAA TCZZA...
Page 108
5 — SoC based ONT functional blocks 5-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 109
6.2 LP MDU ONT functional blocks 6.3 O-00240V-A MDU ONT functional blocks 6-10 6.4 Modular ONT and plug-in unit functional blocks 6-13 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
VDSL LP MDU ONT has been removed. The FPGAs move from the motherboard to the service board and are updated to support 12 10/100/1000BASE-T Ethernet interfaces. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
VDSL VDSL VDSL LD 2 Ports 18964 Figure illustrates the motherboard and service board functional blocks for the GE LP MDU ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The GPON MAC FPGA interacts with the optical functions and provides GPON MAC functions. Table describes the features of the GPON MAC FPGA. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Supports 1 Mb of on-chip data packet memory memory On-board controller The OBC provides the communication control processing functions to the multilayer switch and the service board. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
100 packets for verification. The loopback is intended for hardware lab testing only. Temperature Interfaces with the OBC. sensor July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
JTAG boundary scan interface, which is used for production. VDSL2 subsystem The service board provides the VDSL2 subsystem functions as described in Table 6-8. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Note Sixteen Radio Frequency Interference (RFI) bands can be configured for the 7342 ISAM FTTU. Not every RFI band listed in International Telecommunication Union (ITU) specification ITU-R PN.525-2 can be configured. For more information on supported RFI bands, contact your Alcatel-Lucent support representative.
3 or 4. RF video amplifier The 7342 ISAM FTTU supports video overlay over the GPON that terminates at the LP MDU triplexer. The video overlay signals are sent to an amplifier that converts the video overlay signals into RF video signals. The function operates in the 1550 nm optical band.
GPON MAC FPGA and the VDSL2 chips is the major difference between the O-00240V-A MDU ONT and earlier GPON MDU implementations. 6-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
MDU ONT and an P-OLT. The encoding introduces redundancy, which allows the decoder to detect and correct the transmission errors. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 6-11 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
MDU ONT board Used to connect the OBC to the Ethernet switch (1 of 2) 6-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
• control and management connections • • plug-in service units time calibration Figure shows the functional blocks of the modular ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 6-13 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Table 6-14 describes the industry standards supported by the modular ONT GPON MAC FPGA that provides media access control functions. 6-14 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The OBC provides the communication control and processing functions, as well as management functions to the multilayer switch and the service units. The OBC provides the functions as described in Table 6-16. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 6-15...
Line processor Line end (AFE) protection (DSP) drivers 4 channels function 4 channels SU FPGA configuration Data and video subsystem 18125 6-16 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The FPGA generates the VoIP subsystem NTR clock. All other voice network synchronization clocks are locally generated on the service unit. The GPON MAC FPGA provides NTR for POTS services. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 6-17 3FE 51892 AAAA TCZZA...
NTP protocol and authenticates NTP servers with a provisionable security key. If NTP is not used, the ONT receives time calibration from the OLT. 6-18 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
7.8 Modular ONT and plug-in unit connections and components 7-29 7.9 Business and SOHO ONT connections and components 7-34 7.10 Cable storage compartments 7-40 7.11 Location options 7-44 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Overview This chapter provides information about ONT deployment planning. Equipment options The 7342 ISAM FTTU system provides ONTs that are deployed at the subscriber location to connect the subscribers to the GPON for services. The following ONTs are supported: •...
Page 129
The O-421E-B part number 3FE 50683 AE has an OptiTap connector. (10) The O-821G-D SOHO outdoor ONT has an OptiTap connector. SOHO ONTs have phase lock loop (PLL) locked to the PON. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA...
Connections to the SC/APC and RJ-45 ports are on the outside of the ONT. Figure shows the indoor ONT physical connections for the I-020E-B and I-020E-H. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
SC/APC connector and fiber splice tray. Connections to the RJ-45, RJ-11, and coaxial connectors are on the outside of the ONT. Figure shows the I-221E-A indoor ONT physical connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The I-221E-A and the I-220E-A use the same enclosure but each support different connections. Plastic plugs cover unavailable ports. Figure shows the fiber storage tray and internal SC/APC connector. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The Ethernet port can support both data and in-band video services Power This connection is provided through a cable to the ac/dc power converter. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The I-040G-A ONT is for indoor deployment and can be installed vertically or horizontally. Connections to the SC/APC and RJ-45 connectors are on the outside of the ONT. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The I-211M-E indoor ONT is designed for in-wall installations in pre-constructed telecommunications cabinets or on-wall installations in a telecommunications room. Figure shows the I-211M-E indoor ONT with the inner cover closed. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
ALARM SILENCE BATTERY EMERGENCY 19136 Figure shows the I-211M-E indoor ONT with the inner cover open and the physical connections labeled. 7-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The I-211M-D ONT is an integrated device that serves a variety of network needs with different interfaces. Figure shows the location of the connectors for the interfaces on an I-211M-D. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-11 3FE 51892 AAAA TCZZA...
Type F connector that supports RG-6, and series 7 coax cables for CATV and MoCA connection PON optical SC/APC or OptiTap connectors for GPON connection connectors (1 of 2) 7-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Fiber storage Ethernet port tray Optional cable strain relief OPSU 19572 Table defines the connectors on the I-211M-G ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-13 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
7-10 shows the O-421E outdoor ONT with the inner cover closed as well as cable entry points and enclosure locking mechanisms. 7-14 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Subscriber padlock eyelet position Voice, data, video, power, alarms, and ground port 18222 Figure 7-11 shows the O-421E outdoor ONT physical connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-15 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
F type coaxial connector Ground wire terminal 18746 Figure 7-12 shows the Gemtek dongle that can be used with the O-421E-B outdoor ONT. 7-16 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
This connection is provided through a screw-down terminal, IDCs, or an RJ-11 port. Up to four POTS connections are supported, depending on the outdoor ONT model. (1 of 2) 7-18 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 145
O-211M-R ONT also supports RF return path connections but implements the feature differently; see Table 7-13 for details. Figure 7-14 shows the O-211M-G (AE) outdoor ONT physical connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-19 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
PON. Power and alarm Power and alarm connections to an external UPS with support for battery connections alarms are provided. 7-20 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
F type coaxial down connection Craft port (MOCA) Ground wire terminal connector 19559 Table 7-12 describes the outdoor ONT O-211M-G (BE) physical connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-21 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
IPTV support at any one time. Figure 7-16 shows the O-211M-R outdoor ONT physical connections. 7-22 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
This connection is provided through a connector for a coaxial cable connection located on the Alloptic MicroNode 190 Return Path Transmitter (RPT) integrated into the ONT unit. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-23 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
LP MDU components when installed in an enclosure. This example shows either a O-24121V-A or O-24120V-A outdoor ONT with RF video. 7-24 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
LP MDU ONT by an Ethernet cable once the SWRD is installed and an Ethernet UNI is provisioned. The SWRD is separately orderable. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-25 3FE 51892 AAAA TCZZA...
Data connector alarm button 19117 Table 7-15 describes the O-24121G-A and O-24120G-A outdoor ONT physical connections. 7-26 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
3FE 51185 AB variant of the O-24121G-A and O-24120G-A outdoor ONT. SWRD mounted with an LP MDU connections and components Figure 7-20 shows the SWRD for an enclosure-mounted LP MDU. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-27 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The following sections describe the O-00240V-A MDU ONT model and its connections. O-00240V-A ONT connections and components Figure 7-21 shows the O-00240V-A MDU ONT physical connections. 7-28 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The following section describes the modular ONT and plug-in unit connections. Figure 7-22 and Table 7-18 describe the modular ONT physical connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-29 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The modular ONT front door is equipped with tamper-resistant screws to prevent unauthorized entry; see Figure 7-23. A second internal cover protects access to fiber and power terminals; see Figure 7-24. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-31...
Warning — Do not submerge the modular ONT. The modular ONT cannot withstand water submersion caused by flooding. Equipment damage will occur. 7-32 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
18361 Within the enclosure assembly, the modular ONT motherboard provides power and traffic management, and accommodates optical, power, and common circuitry for the S-840V-As; see Figure 7-25. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-33 3FE 51892 AAAA TCZZA...
ONT). Business and SOHO ONT connections and components The following section describes the business ONT and SOHO outdoor ONT components. 7-34 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Figure 7-27 shows a SOHO or business ONT with the inner covers protecting the fiber, and the power and alarm connections. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-35 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
B-8112-A business ONT physical connections. The B-8102-A has exactly the same layout and connectors, except that the RF video port is not available. 7-36 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
POTS connection This connection is provided through RJ-11 ports and either screw-down terminals or IDC connectors, depending upon the model. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-37 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
IN VIOLATION OF THE FCC RULES, PART 15. VIDEO IDC connector (Optional) Class 1 power and F-type fiber conduit box coaxial 18884 7-38 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
POTS connection This connection is provided through RJ-11 ports and either screw-down terminals or IDC connectors, depending upon the model. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-39 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The outdoor, SOHO, and business ONTs support cable storage compartments. The following sections describe these compartments. 3EM 17661 AB compartment Figure 7-31 shows the cable storage compartment. 7-40 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Optional ONT Optional ONT mounting point mounting point ONT mounting point 18811 Figure 7-34 shows the cable storage compartment with mounting bracket. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 7-43 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
SWRD, IDC, punchdown blocks, or screw terminals. The indoor ONT is not temperature-hardened and must be installed inside a single residence. 7-44 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 171
7 — ONT equipment layout Temperature hardened ONTs can be installed in a closet, a terminal room, or outside the building on a wall or a pole. Alcatel-Lucent recommends using mounting hardware that is in compliance with GR-950 corrosion requirements.
Page 172
7 — ONT equipment layout 7-46 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
UPS LEDs The ONTs use a variety of UPS equipment, so LED status indicators vary depending on the type of UPS equipment deployed. July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Bad battery power battery power shutdown condition AC Present Green Yellow Green Green or yellow DC Output Green Green Green Battery Bad Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Operating on ac power Green High-charge mode flashing Yellow Operating on battery OUTPUT Green DC output is present BATTERY Battery is missing or needs replacement July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Battery missing or failed self test and The BBU beeps BATTERY needs replacement once every fifteen minutes. AUXILIARY Green Auxiliary power source is connected — POWER Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Battery missing or failed self test and needs replacement Battery Power Green On Battery Flashing green Low capacity System Status Green Normal operation July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Green Operating on ac power Yellow Operating on battery OUTPUT Green DC output is present BATTERY Battery is missing or needs replacement Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 180
8 — UPS LEDs July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 181
9.2 Outdoor ONT LEDs 9.3 Indoor (I-series) ONT LEDs 9-11 9.4 Modular ONT and service unit LEDs 9-18 9.5 Business ONT LEDs 9-21 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
AC FAIL RPLC BATT BATT MISS LOW BATT LINK MODE RJ-45 status LEDs LINK MODE LINE LINE LINE LINE ONT status LEDs 18211 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
LINE MGMT INTF LINE POTS LINE MOCA ETHERNET Ethernet port 1 RJ-45 status LEDs ETHERNET Ethernet port 2 RJ-45 status LEDs 18889 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Activity (approximately 1 s on, 1 s off) Notes The VID LED is only functional for RF video-equipped ONTs. The MOCA LED is only functional for MOCA equipped ONTs. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
— (aggregate) (Ethernet or MoCA) NTWK 1490 nm data path is 1490 nm data path is — unavailable/non-operational available/operational (1 of 2) July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
No activity on Ethernet link Activity on Ethernet link — Table 9-10 provides descriptions of the various LEDs on the O-00240V-A MDU ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
LINK Link down/inactive Ethernet link up/active (data in — either direction) No activity on Ethernet link Activity on Ethernet link — 9-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
LEDs and audible alarms for I-211M-D ONTs • Table 9-21 provides descriptions for the user control buttons on I-211M-D ONTs Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-11 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Figure 9-5 Indoor ONT LEDs (I-221E-A and I-220E-A) No1007 Figure 9-6 Indoor ONT LEDs (I-020E-B, I-020E-H, I-020G-F, and I-020G-G) EQPT Data 2 Data 1 MGMT 18794 9-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Ranging Loss of physical layer, startup failure, or link mismatch Red flashing ONT disabled Amber BIP errors detected (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-13 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Power is available BTRY Battery low or battery missing Green Battery good, charged, and there is no battery alarm (1 of 2) 9-14 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Ethernet 3 link is in Tx/Rx activity NTWK 1490 nm data path is unavailable Green 1490 nm data path is available (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-15 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Link active Green flashing Link detected and activity present MODE 10 Mb/s operation Green 100 Mb/s operation Green flashing 1000 Mb/s operation 9-16 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Battery missing or failed self test and The BBU beeps BATTERY needs replacement once every fifteen minutes. AUXILIARY Green Auxiliary power source is connected — POWER Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-17 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
LEDs • Table 9-22 provides LED descriptions for modular ONTs • Table 9-23 provides LED descriptions for service unit LEDs 9-18 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
18359 Figure 9-10 Service plug-in unit LEDs S-840V-A status LEDs DAT_EQMT POTS DAT 4 DAT 3 DAT 2 DAT 1 18345 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-19 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
VDSL line 3 DAT2 Indicates data activity on VDSL line 2 DAT1 Indicates data activity on VDSL line 1 9-20 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
BTRY Battery alarm set or battery not provisioned Green Battery good, charged, and there is no battery alarm (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 9-21 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 202
EQPT Not provisioned TDM equipment problem ENV.374 (2 of 2) Note The VID LED is only functional for RF video-equipped ONTs. 9-22 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
1000 m (3280.8 ft) O-24121G-A and O-24120G-A MDU ONT Table 10-2 lists the physical specifications of the O-24121V-A and O-24120V-A MDU ONT. 10-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
4.0 lb (1.81 kg) Indoor ONT (I-020E-B, I-020G-F, I-020G-G, and I-020E-H) Table 10-6 lists the physical specifications of the I-020E-B, I-020G-F, I-020G-G, and I-020E-H. 10-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Indoor ONT (I-211M-E) Table 10-9 provides the physical specifications for the I-211M-E MoCA indoor ONT excluding back plate, OPSU/BBU, and battery. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
I-211M-G ONT equipped with an OPSU, skirt, and cable storage tray. The skirt is designed to work with the cable storage tray attached. 10-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Business and SOHO ONTs Table 10-15 provides the physical specifications for the business and SOHO ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
-4°F to 122°F (-20°C to 50°C) pre-constructed 5% to 95% humidity range, non-condensing telecommunications cabinet 5% to 85% humidity range, non-condensing (I-211M-E only) (1 of 3) 10-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 211
40 000 ft (12 192 m) above mean sea –40°F to 158°F (–40°C to 70°C) level 10% to 95% relative humidly, non-condensing (2 of 3) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-9 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 212
5% to 95% relative humidly, non-condensing level (3 of 3) Notes The maximum solar load is 1120 W/m Solar loading per GR-950. 10-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Alcatel-Lucent recommends the following: • When transitioning the packaged unit from one environmental condition to another, let the unit remain in the sealed packaging until it has stabilized to the new environment.
57 Mb/s downstream and 25 Mb/s upstream, compared with 24 Mb/s downstream and 1.3 Mb/s upstream 10-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Note 1 — See the 7342 ISAM FTTU Product Information Manual for more information about the RF video service. Note 2 — Alcatel-Lucent only guarantees ONT RF video output levels.
Table 10-20 Cable attenuation loss value based on frequency Frequency (MHz) RG-6 coaxial per 100 ft (dB) RG-59 coaxial per 100 ft (dB) (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-15 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
You can set high and low optical power level thresholds for the downstream signal. An alarm is raised if either the high or the low optical power level threshold is crossed. 10-16 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
RF video service configuration requires the use of TL1 commands. These commands are issued at the P-OLT craft terminal. For detailed information about the parameters of each command and response messages, refer to the 7342 ISAM FTTU P-OLT and ONT Operations and Maintenance Procedures manual.
40 analog and 63 digital 0 analog and 135 digital Digital backoff QAM-256 6 dB (QAM-256) 6 dB (QAM-256) 6 dB (QAM-256) (1 of 2) 10-18 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
TV, VCR, and STB, is between 0 to 33 dBmV. The transmitter and backbone segment is assumed to have a CSO greater than 62 dB for any channel load conditions. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008...
Forward pass band 46 to 870 Reverse operating frequency 18.5 Maximum length of power supply — 50 ft (15.24 m) coaxial cable 10-20 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
• weight of MNTH191 (ANSI standards) is 0.43 lbs (0.2 kg) • weight of MNTH192 (ETSI standards) is 0.21 lbs (0.1 kg) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-21 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Operation time of the automatic power reduction of the ONT transmitted optical power is 1 s or less. 10.12 Power consumption The following sections describe power consumption ranges for Alcatel-Lucent ONTs. Outdoor ONTs For all outdoor ONTs, you can connect input power using either the screw-down terminals or the multi-position IDC connector.
-2, -3, -4 — 0, -1 — Outdoor ONT (O-420E-B) Table 10-28 provides the power consumption specifications for the O-420E-B outdoor ONT. 10-24 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
See the appropriate ONT data sheet for specific UPS support. Indoor ONT (I-020G-F and I-020G-G) Table 10-31 provides the power consumption specifications for the I-020G-F and I-020G-G indoor ONTs. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-25 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
(2 POTS lines on-hook, no RF video, or GE ports provisioned.) Indoor ONT (I-220E-A and I-221E-A) Table 10-34 provides the power consumption specifications for the I-220E-A and I-221E-A indoor ONT. 10-26 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
2.5 A fuse within the in-wall MoCA indoor ONT Indoor ONT (I-211M-D) Table 10-36 provides the power consumption specifications for the I-211M-D ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-27 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
DC power supply with LPS or Class 2 outputs, suitably approved and rated for the application. Outputs at SELV/LPS levels rated for 48 V dc, 3.124 A are required. The UPSs that are Alcatel-Lucent approved for use with the SOHO include the following: •...
10-40 provides the transmit output power variance for SOHO ONTs using MoCA. These variances assume no board implementation loss or impedance mismatches. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-29 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
B-xxxx-x ONTs require 48 V DC input power supplies. See the appropriate ONT data sheet for specific UPS support. Alcatel-Lucent recommends the use of a listed DC power supply with LPS or Class 2 outputs, suitably approved and rated for the application.
ONT data sheet for specific UPS support. Table 10-44 lists the measured power consumption values for a typical O-00240V-A MDU outdoor ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-31 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
18 V (dc) offset (sinusoidal or trapezoidal): 40 Vrms • audio output for voice: up to +6 dBm • VDSL output level: up to +8.5 dBm 10-32 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
11.2 ONT performance monitoring 11-2 11.3 ONT performance monitoring functions 11-2 11.4 ONT performance monitoring data 11-3 11.5 ONT performance reporting 11-9 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 11-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
• plan for development and growth 11.3 ONT performance monitoring functions 7342 ISAM FTTU provides the following functionality to simplify the usage of performance monitoring tools: • Monitor at the edges per subscriber and per aggregate: The system provides counters at the edges where the subscriber originates and terminates. For example, these counters are performed on the ONTs and edge devices such as BRAS or Edge Router.
You can enable or disable counters using TL1. Counters are disabled by default unless indicated otherwise. Some counters have restrictions for the total number that you can activate at the same time. See the 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI document for information about any restrictions that apply to each performance statistic type.
Table 11-1 Performance monitoring statistics supported for the indoor, outdoor, and business ONTs Statistics Indoor ONTs Outdoor ONTs ONTENET FCSE IMTE ALM_IMRE (1 of 3) 11-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 239
RXERRFRMS PONONTTC TXBLOCKS TXFRAGS RXBLOCKS RXFRAGS LOSTFRAGS BADGEMHDRS PONONTTC (aggregate) TXBLOCKS TXFRAGS RXBLOCKS RXFRAGS LOSTFRAGS BADGEMHDRS X/VDSL2 Line (2 of 3) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 11-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 240
Table 11-2 Performance monitoring statistics for the business, modular, VDSL2 LP MDU, and GE LP MDU ONTs Statistics Business ONTENET FCSE (1 of 3) 11-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 241
PONONTTC (aggregate) TXBLOCKS (not applicable) TXFRAGS RXBLOCKS (not applicable) RXFRAGS LOSTFRAG (not applicable) BADGEHDRS X/VDSL2 line LOSS LOFS (2 of 3) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 11-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 242
(fast) is reported for the modular ONT; only the count of code violations and forward error corrections are reported for the VDSL2 LP MDU ONT. 11-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
11 — ONT statistics and performance monitoring 11.5 ONT performance reporting The 7342 ISAM FTTU provides facilities that enable you to do the following: • view statistics • generate alarms • report status • capture diagnostic data ONT statistical viewing You can view statistics collected for the ONT using a TL1, CLI, or an EMS management session with the P-OLT.
EMS management session with the P-OLT. A snapshot of the current value in the rolling counter is displayed as an integer. Table 11-4 lists the rolling counters the 7342 ISAM FTTU uses to collect performance monitoring statistics. Table 11-4 Rolling counters Counter description GPON ports Some rolling counters can be set to automatically reset to zero after being retrieved.
ONT optical link status levels • ONT VDSL2 channels and ports See the 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI document for statistical parameters that are displayed in status reports. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
• Quantity of traffic flowing through the ONT at time of receipt of request • State of the software load images 11-12 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
25 — O-211M-C, O-211M-E, and O-211M-G unit data sheet 26 — O-211M-R unit data sheet 27 — O-420E-B and O-421E-B unit data sheet Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 248
30 — O-24121G-A and O-24120G-A unit data sheet 31 — O-24121V-A and O-24120V-A unit data sheet 32 — O-00240V-A unit data sheet July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
12 — Index of ONT unit data sheets 12.1 Overview 12-2 12.2 Unit data sheet overview 12-2 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 12-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
12.1 Overview Table 12-1 lists the sections in this chapter that provide overview information about ONT unit data sheets. Table 12-1 Overview of unit data sheets for the 7342 ISAM FTTU Description Section Unit data sheet overview 12.2 12.2 Unit data sheet overview Unit data sheets provide detailed information about ONTs produced by Alcatel-Lucent for the 7342 ISAM FTTU.
13 — B-8102-A and B-8112-A unit data sheet 13.1 Identification 13-2 13.2 General description 13-2 13.3 Hardware and software features 13-2 13.4 Special considerations 13-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 13-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
3FE 50774 AF GPON, 8 POTS, 1 Ethernet, and 2 DS1/E1. Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 13.2 General description The business ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
PowerShield CP50B48 UPS unit data sheet FlexNet FMPS-150W UPS unit data sheet Table 13-3 describes software based features for the B-8112-A and the B-8102-A. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 13-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 13.4 Special considerations None. 13-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
14 — I-020E-B and I-020E-H unit data sheet 14.1 Identification 14-2 14.2 General description 14-2 14.3 ONT hardware and software features 14-2 14.4 Special considerations 14-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 14-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0009 connector, 3-conductor, 10 A, 250 V ac, 1.78 m, black (Australia/China) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information, including additional AC/DC power converter cabling information. 14.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
I-020E-B and I-020E-H unit data sheet 12 v AC/DC power converter and cable, as listed in Table 14-1 or in the 7342 ISAM FTTU ONT Planning and Ordering Guide. Note The POTS DSP is not used for these ONTs. Table 14-3 describes software based features for the I-020E-B and the I-020E-H.
— information in FLASH memory via push button or EMS Note The I-020E-B does not support AES. 14.4 Special considerations None. 14-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
15 — I-020G-F unit data sheet 15.1 Identification 15-2 15.2 General description 15-2 15.3 ONT hardware and software features 15-2 15.4 Special considerations 15-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 15-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0009 connector, 3-conductor, 10 A, 250 V ac, 1.78 m, black (Australia/China) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information, including additional AC/DC power converter cabling information. 15.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The FCC and UL compliant ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Supported UPS I-020G-F unit data sheet 12 v AC/DC power converter and cable, as listed in Table 15-1 or in the 7342 ISAM FTTU ONT Planning and Ordering Guide. Note The POTS DSP is not used for these ONTs. Table 15-3 describes software based features for the I-020G-F.
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 15.4 Special considerations None 15-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
16 — I-020G-G unit data sheet 16.1 Identification 16-2 16.2 General description 16-2 16.3 ONT hardware and software features 16-2 16.4 Special considerations 16-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 16-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0009 connector, 3-conductor, 10 A, 250 V ac, 1.78 m, black (Australia/China) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information, including additional AC/DC power converter cabling information. 16.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The FCC and UL compliant ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Supported UPS I-020G-G unit data sheet 12 v AC/DC power converter and cable, as listed in Table 16-1 or in the 7342 ISAM FTTU ONT Planning and Ordering Guide. Note The POTS DSP is not used for these ONTs. Table 16-3 describes software based features for the I-020G-G.
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 16.4 Special considerations None 16-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
17 — I-040G-A unit data sheet 17.1 Identification 17-2 17.2 General description 17-2 17.3 ONT hardware and software features 17-2 17.4 Special considerations 17-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 17-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
17.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber...
Supported ONT counters performance monitors monitoring Retrievable ONT repair and return — — information in FLASH memory via push button or EMS Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 17-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
4 are each set to 1000Base-T and are being used simultaneously. See the ONT Customer Release Notes for this product for throughput details. 17-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
56 to 63 Note Where x is a number from 0 to 7. All VLAN tagging behavior operates as described in the 7342 ISAM FTTU Product Information Manual except as indicated in the following sections. Upstream traffic handling (trusted and untrusted)
C-VLAN. A network (NW) C-VLAN is used when data is sent over the GPON network, and a user network interface (UNI) side C-VLAN is used when data is sent to customer equipment. 17-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
C-VLAN and Ethertype must match the default NW C-VLAN an Ethertype or the packet is dropped. See the 7342 ISAM FTTU Product Information Manual for more information on Ethertype classification. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
Page 274
17 — I-040G-A unit data sheet 17-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
18 — I-211M-D unit data sheet 18.1 Identification 18-2 18.2 General description 18-2 18.3 ONT hardware and software features 18-3 18.4 Special considerations 18-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 18-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
PXL12072 ONT. PWL12V7 Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 18.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Location options Temperature and humidity range ONT technical specifications Temperature and humidity range Fiber storage compartment — — (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 18-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 18.4 Special considerations None. 18-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
19 — I-211M-E unit data sheet 19.1 Identification 19-2 19.2 General description 19-2 19.3 ONT hardware and software features 19-3 19.4 Special considerations 19-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 19-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
(This variant provides no logo.) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 19.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
SLID entry via Ethernet — — interface Supported UPS — — Table 19-3 describes software based features for the I-211M-E ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 19-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 19.4 Special considerations None. 19-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
20 — I-211M-G unit data sheet 20.1 Identification 20-2 20.2 General description 20-2 20.3 ONT hardware and software features 20-3 20.4 Special considerations 20-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 20-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
PXL12072 ONT. PWL12V7 Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 20.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Location and installation options ONT equipment layout Location options Temperature and humidity range ONT technical specifications Temperature and humidity range (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 20-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 20.4 Special considerations None. 20-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
21 — I-221E-A and I-220E-A unit data sheet 21.1 Identification 21-2 21.2 General description 21-2 21.3 ONT hardware and software features 21-3 21.4 Special considerations 21-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 21-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0009 connector, 3-conductor, 10 A, 250 V ac, 1.78 m, black (Australia/China) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information, including additional AC/DC power converter cabling information. 21.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Supported UPS I-221E-A and I-220E-A unit data sheet 12 v AC/DC power converter and cable, as listed in Table 21-1 or in the 7342 ISAM FTTU ONT Planning and Ordering Guide. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 21-3...
FLASH memory via push button or EMS Note The 3FE 50754 AA and 3FE 50754 AB do not support AES. 21.4 Special considerations None. 21-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
22 — I-241G-A and I-240G-A unit data sheet 22.1 Identification 22-2 22.2 General description 22-2 22.3 ONT hardware and software features 22-3 22.4 Special considerations 22-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 22-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
22.2 General description The indoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber...
Supported UPS I-241G-A and I-240G-A unit data sheet 12 v AC/DC power converter and cable, as listed in Table 22-1 or in the 7342 ISAM FTTU ONT Planning and Ordering Guide. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 22-3...
VLAN tagging to direct traffic to appropriate ports and priority queues Figure 22-1 Ethernet switch Power Converter RJ-11 POTS GPON Triplexer Ethernet RJ-45 switch Video amplifier 19394 22-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
• Default P-bits must be configured on each Ethernet port. This can be configured using the ENT-QOS-MARKPROF command described in the 7342 ISAM FTTU Operations and Maintenance Procedures Guide using TL1 and CLI. • DSCP to 1P mapping rules are reduced from 64 to 8 with only the highest 3 bits of the DSCP area used to determine P-bit value;...
56 to 63 Note Where x is a number from 0 to 7. All VLAN tagging behavior operates as described in the 7342 ISAM FTTU Product Information Manual except as indicated in the following sections. Upstream traffic handling (trusted and untrusted)
Received UNI C-VLAN and P-bits must match NW C-VLAN packets configure P-bits or the packet is dropped. Table 22-8 describes downstream VLAN tagging behavior for VLAN translation. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 22-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
VLAN translation section apply with the additional that the received C-VLAN and Ethertype must match the default NW C-VLAN an Ethertype or the packet is dropped. See the 7342 ISAM FTTU Product Information Manual for more information on Ethertype classification. 22-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
23 — M-300-A and S-840V-A unit data sheet 23.1 Identification 23-2 23.2 General description 23-2 23.3 ONT hardware and software features 23-2 23.4 Special considerations 23-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 23-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
BVL2MR0BAA 070AZF 138487 Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. Note — Currently the M-300-A and the S-840V-A are only supported in the ANSI market and DELT is not supported on the M-300-A ONT.
802.1X support for Ethernet ports ONT software and security features 802.1x authentication AES support ONT software and security features (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 23-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS (2 of 2) 23.4 Special considerations None. 23-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
24 — O-210E-B and O-211E-B unit data sheet 24.1 Identification 24-2 24.2 General description 24-2 24.3 ONT hardware and software feature 24-3 24.4 Special considerations 24-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 24-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
RF video, EPC jumper for +12V PoE, craft interface, and OptiTap interface Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 24.2 General description The outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
SLID entry via craft terminal interface SLID entry via POTS ONT software and security features SLID entry via first POTS port interface (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 24-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The following outdoor ONTs do not support AES: 3FE 50683 AF, 3FE 50683 AH, 3FE 50683 AC, and 3FE 50683 AG. 24.4 Special considerations None. 24-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
25.1 Identification 25-2 25.2 General description 25-2 25.3 ONT hardware and software features 25-3 25.4 Special considerations 25-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 25-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
RF video and later release MoCA interface, SC/APC interface, no vendor-specific logo Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 25.2 General description The outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
ONT optical budget Power consumption ONT technical specifications Power consumption Location and installation ONT equipment layout Location options options (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 25-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 25.4 Special considerations None. 25-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
26 — O-211M-R unit data sheet 26.1 Identification 26-2 26.2 General description 26-2 26.3 ONT hardware and software features 26-2 26.4 Special considerations 26-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 26-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
1 Gigabit Ethernet interface, 1 RF video and MoCA interface, and SC/APC interface Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 26.2 General description The outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
UPS unit data sheets CyberPower CyberShield CS 24 UPS unit data sheet Table 26-3 describes software based features for the O-211M-R outdoor ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 26-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 26.4 Special considerations None. 26-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
27 — O-420E-B and O-421E-B unit data sheet 27.1 Identification 27-2 27.2 General description 27-2 27.3 ONT hardware and software features 27-3 27.4 Special considerations 27-5 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 27-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
2 Ethernet interfaces for both data and IP video, craft interface, and OptiTap interface Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 27.2 General description The outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
Power consumption ONT technical specifications Power consumption Outdoor ONT (O-420E-B) Location and installation ONT equipment layout Location options options (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 27-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
FLASH memory via push button or EMS Note The following outdoor ONTs do not support AES: 3FE 50683 AA and 3FE 50683 AD. 27-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
100 BT Dongle AMR iB AMR CVLAN AMR VLAN = 4038 IPTV SVLAN = MC VLAN AMR SVLAN = NW CVLAN 19828 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 27-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 320
27 — O-420E-B and O-421E-B unit data sheet 27-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
28 — O-820G-D and O-821G-D unit data sheet 28.1 Identification 28-2 28.2 General description 28-2 28.3 ONT hardware and software features 28-2 28.4 Special considerations 28-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 28-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
211016 454270 The AJ variant uses an SC/APC connector. Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 28.2 General description The SOHO outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
CyberPower CyberShield CS 50 UPS unit data sheet FlexNet FMPS-150W UPS unit data sheet Table 28-3 describes software based features for the O-811G-D and the O-810G-D. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 28-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
EMS Note The following SOHO ONTs do not support AES: 3FE 50744 AC and 3FE 50744 AG. 28.4 Special considerations None. 28-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
29 — O-821M-E unit data sheet 29.1 Identification 29-2 29.2 General description 29-2 29.3 ONT hardware and software features 29-2 29.4 Special considerations 29-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 29-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The AC and AD variants use and support a later release of MoCA functionality. Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 29.2 General description The SOHO outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU.
Supported UPS UPS unit data sheets FlexNet FMPS-150W UPS unit data sheet Table 29-3 describes software based features for the O-821M-E. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 29-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 29.4 Special considerations None. 29-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
30 — O-24121G-A and O-24120G-A unit data sheet 30.1 Identification 30-2 30.2 General description 30-4 30.3 Features and application notes 30-5 30.4 Special considerations 30-6 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 30-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
This BA variant supports the RF variant LP MDU and provides: • rear fiber storage • OptiTap fiber connector • IDC POTS connectors (1 of 3) 30-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 331
• OptiTap fiber connector • punchdown POTS connectors • Door switch alarm capability • Squeeze box cable conduits (2 of 3) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 30-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
• Squeeze box cable conduits (3 of 3) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 30.2 General description The O-24121G-A and O-24120G-A MDU outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
UPS unit data sheets FlexNet FMPS-150W UPS unit data sheet Table 30-3 describes software based features for the O-24121G-A and O-24120G-A MDU outdoor ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 30-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 30.4 Special considerations None. 30-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
31 — O-24121V-A and O-24120V-A unit data sheet 31.1 Identification 31-2 31.2 General description 31-4 31.3 Features and application notes 31-5 31.4 Special considerations 31-6 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 31-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
• Squeeze box cable conduits (3 of 3) Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 31.2 General description The O-24121V-A and O-24120V-A MDU outdoor ONT provides the subscriber interface for the 7342 ISAM FTTU. The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices.
UPS unit data sheets FlexNet FMPS-150W UPS unit data sheet Table 31-3 describes software based features for the O-24121V-A and O-24120V-A ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 31-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Retrievable ONT repair and return — — information in FLASH memory via push button or EMS 31.4 Special considerations None. 31-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
32 — O-00240V-A unit data sheet 32.1 Identification 32-2 32.2 General description 32-2 32.3 Features and application notes 32-2 32.4 Special considerations 32-3 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 32-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
456763 24 VDSL2 ports, 1 Ethernet interface, and SC/APC connector type Note See the 7342 ISAM FTTU ONT Planning and Ordering guide for product identification information. 32.2 General description The O-00240V-A MDU outdoor ONT provides the VDSL2 interface with VDSL2 modems at the subscriber’s premises.
Since there are no individual LEDs on the O-00240V-A MDU outdoor ONT for the line status of each VDSL2 port, a craft command is used to retrieve port status from the local craft interface. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 32-3...
32-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 345
41 — Delta DUPS-1232A UPS unit data sheet 42 — FlexNet FMPS-150W UPS unit data sheet 43 — PowerShield CP50B48 UPS unit data sheet Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 346
July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
33 — Index of unit data sheets for UPSs 33.1 Overview 33-2 33.2 Unit data sheet overview 33-2 33.3 UPS functional comparison 33-2 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 33-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 348
• alarm LEDs • interfaces and connections • power Many of the UPS units are used in more than one Alcatel-Lucent ONT product. For information about the UPS units see the information . 33.3 UPS functional comparison Table 33-2 lists and compares 24 and 38 W UPS specifications for ONTs.
Listed by an NRTL — — Notes Depending upon external conditions and load. Current limited using a 2.5 A fuse installed inside the ONT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 33-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 350
33 — Index of unit data sheets for UPSs 33-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 351
34-2 34.4 Operating modes and LEDs 34-3 34.5 Alarms 34-5 34.6 Connectors 34-5 34.7 Environmental requirements 34-6 34.8 Physical measurements 34-6 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 34-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
ONT via a signal return connection. The outdoor ONT can communicate this status upstream to the P-OLT. 34-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
If the UPS shuts down due to overload, it automatically restarts after 6 s. Replace battery. If the outdoor ONT power cable with beeper assembly is installed, an audible alarm sounds. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 34-3...
Battery and/or ac power is in use. If both Battery needs to be replaced. AC Present and DC Output LED lights are off, the UPS battery has shut down. 34-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Black (BLK) Signal Return Green (GRN) On-Battery Slate (SLT) Replace Battery Brown (BRN) Battery Missing Orange (ORN) Low Battery Blue (BLU) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 34-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Measurement Height 7.5 in. (19.1 cm) Width 9.5 in. (24.1 cm) Depth 3.1 in. (8.9 cm) Weight 7.0 lb. (3.2 kg) 34-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 357
35.3 General description 35-2 35.4 Operating modes 35-3 35.5 Status LEDs 35-3 35.6 Alarms 35-4 35.7 Connections 35-4 35.8 Specifications 35-5 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 35-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
• easy replacement of the battery by a craft person while the unit is powered Note — If the plug is not the right type, please contact Alcatel-Lucent support for a recommended adapter. 35.3 General description The APC UPS is mounted either inside or outside a customer premises. It provides backup battery power for lifeline POTS service in the modular ONT, depending on environmental conditions and load.
Green Flashing High-charge mode Yellow Operating on battery DC Output On Green DC output present Battery Bad Battery missing or needs replacement Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 35-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Low Battery Blue (BLU) Notes Tied to earth ground. –48 V reference to pin 1. Figure 35-2 shows the output connectors. 35-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The UPS has the following output specifications: • output voltages: 50 • output power capacity: 150 VA, 150 W • maximum configurable power: 150 VA, 150 W Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 35-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
• elevation: 0 to 10 000 ft above sea level (0 to 3000 m) • humidity (non-condensing): 0% to 95% RH 35-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
36.2 Features and application notes 36-2 36.3 General description 36-2 36.4 Output connections on the PowerShield 36-3 36.5 Alarm descriptions 36-3 36.6 Interface details 36-4 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 36-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
REPLACE BATT beep sound for 24 h. If the battery has not been replaced after 24 h, the REPLACE BATT beep sound resumes. Figure 36-1 APC cable assembly with beeper 18341 36-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Closed Open Orange Low Battery Closed Open Blue 36.5 Alarm descriptions Table 36-4 describes the status alarms received from the UPS. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 36-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
TTL levels. The 10 Ω resistor and capacitor on each output signal provide ESD protection. 36-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
UL 605950-1, CSA C22.2 No. 60950-1, NEBS Level 1 and 3 (GR1089 and GR63), FCC Part 15 Class B Note — If the plug is not the correct type, please contact the local Alcatel-Lucent support group for a recommended adapter. 37-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
The replace-battery alarm indicates that the battery is either discharged, or has failed the self test. Replace the battery if there is a failure. (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 37-3 3FE 51892 AAAA TCZZA...
- 12 V RTN Green (GRN) SIG RTN Slate (SLT) ON BATTERY Brown (BRN) REPLACE BATTERY Blue (BLU) BATTERY MISSING Orange (ORN) LOW BATTERY 37-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
8 h with the loading profile defined in GR-1089. Environmental Table 37-6 lists the environmental conditions for the CyberShield CS 24 UPS. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 37-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0% to 100% non-condensing within enclosure Storage: Maximum storage altitude is 50 000 ft (15 000 m) –5°F to 113°F (–40°C to 45°C) 37-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
38-2 38.3 General description 38-3 38.4 Status LEDs and user controls 38-3 38.5 Alarms 38-4 38.6 Connections 38-5 38.7 Specifications 38-6 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
UL 60950-1, CSA C22.2 No. 60950-1, NEBS Level 1 and 3 (GR1089 and GR63), FCC Part 15 Class B Note — If the plug is not the correct type, please contact the local Alcatel-Lucent support group for a recommended adapter. 38-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
Description Audible alarm PSU LED Power OK Green Normal operation — Protected Green Protected from surge voltage — (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The replace-battery alarm indicates that the battery is either discharged, or has failed the self test. Replace the battery if there is a failure. (1 of 2) 38-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Red (RED) 48 V in + Black (BLK) 48 V in – Red (RED) 12 V out + (1 of 2) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
50 W maximum (1.0Amp) • efficiency: > 80% at full load by specification The BBU has 12.5 to 20 V dc auxiliary input voltage. 38-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
–40°F to 115°F (–40°C to 50°C) 0 to 10 000 ft (0 to 3 000 m) Humidity: 0% to 95% non-condensing within enclosure Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 380
38 — CyberPower CyberShield CS 36 PSU/BBU unit data sheet 38-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
GR63), FCC Part 15 Class B Note — If the plug is not the correct type, please contact the local Alcatel-Lucent support group for a recommended adapter. 39.3 General description The UPS converts ac input power (87 to 264 V ac) to dc power (50 W, 48 V dc). The battery provides up to 8 h of backup power for the lifeline POTS service, depending on environmental conditions and load.
Table 39-4 describes the function of the Buzzer On/Off switch. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 39-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0% to 95% non-condensing within enclosure Storage: Maximum storage altitude is 50 000 ft (15 000 m) 5°F to 113°F (–15°C to 45°C) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 39-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 386
39 — CyberPower CyberShield CS 50 UPS unit data sheet 39-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
• Note — If the plug is not the correct type, please contact the local Alcatel-Lucent support group for a recommended adapter. 40.3 General description The OPSU converts ac power to dc power to supply the BBU. The BBU provides 4 to 8 h of backup battery power for the lifeline POTS service, depending on environmental conditions and load.
LED is labeled with an icon. The LEDs and the icons, with their meanings, are shown in Figure 40-1. The operating mode can be determined by the state of these LEDs; see Table 40-2. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 40-3...
— POWER Two user controls blue buttons are present on the front of the BBU; see Figure 40-1 and Table 40-3. 40-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
SIGNAL RETURN Power and ON BATTERY alarm connection REPLACE BATTERY BATTERY OPSU to BBU and MISSING power connector LOW BATTERY 19041 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 40-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Note — The backup battery supports ONT operations for a minimum of 8 h with the loading profile defined in GR-1089. 40-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
The operating conditions are: temperature range: –4 ° to 115 °F (–20° to 46°C) • • relative humidity (non-condensing) within enclosure: 0% to 95% Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 40-9 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 396
40 — Delta OPSU/BBU unit data sheet 40-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
UL 60950-1, CSA C22.2, and NEBS Level 1 and 3 (GR1089 and GR63) Note — If the plug is not the correct type, please contact the local Alcatel-Lucent support group for a recommended adapter. 41-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06...
Each LED is labeled with an icon as well as the user control button as shown in Figure 41-1. For descriptions of these LEDs and the user control button, see Tables 41-2 and 41-3. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 41-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
The alarm silence button disables an audible alarm for 24 hours. After 24 hours, the alarm will recommence if the underlying fault condition has not be corrected. 41-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
DC jack, 3.5 mm (0.14 inch) OD return, 1.3 mm (0.05 inch) ID positive center Figure 41-2 shows the UPS output power and alarm connector. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 41-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
3.07 in. (78 mm) • width: 8.58 in. (218 mm) • depth: 7.05 in. (179 mm) • weight: 7.78 lb (3.53 kg with battery) 41-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
(non-condensing): 0% to 95% The storage conditions are: • temperature range: –4° to 122°F (–20° to 50°C) • relative humidity (non-condensing): 0% to 95% Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 41-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 404
41 — Delta DUPS-1232A UPS unit data sheet 41-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
1AF 14373 AC FlexNet FMPS-150W UPS without heater. 1AF 14373 AD FlexNet FMPS-150W UPS with heater. See the 7342 ISAM FTTU ONT Planning and Batteries for the FlexNet FMPS-150W UPS. Ordering Guide 42.2 Features and application notes The FlexNet FMPS-150W UPS provides: •...
P-OLT. Two dc output and alarm connectors are provided on the UPS; however, Alcatel-Lucent recommends the use of only one dc and alarm connection per UPS for an ONT installation. As well, Alcatel-Lucent recommends running the power wires in a separate conduit from the alarm wires.
You can install one string of four batteries or two strings of eight batteries in the UPS. Alcatel-Lucent recommends installing both strings. If only one string of backup batteries are installed, a battery missing alarm is sent to the ONT.
Two dc output and alarm connectors are provided; however, Alcatel-Lucent recommends the use of only one dc and alarm connection per UPS for an ONT installation. As well, Alcatel-Lucent recommends running the power wires in a separate conduit from the alarm wires.
Page 411
• humidity (non-condensing): 0% to 95% humidity • elevation: 0 to 50 000 ft above sea level (0 to 15000 m) Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 42-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 412
42 — FlexNet FMPS-150W UPS unit data sheet 42-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
50 W, –48 V dc UPS with spill-proof, maintenance-free sealed lead acid backup battery and a 6.5 ft (1.98 m) long power cord with an Australian/New Zealand plug. Note The CP50B48 UPS is manufacturer discontinued. Contact your Alcatel-Lucent representative for details. 43.2 Features and application notes The PowerShield CP50B48 provides: •...
These icons, with their meanings, are shown in Figure 43-1. The operating mode can be determined by the state of these LEDs; see Table 43-2. Figure 43-1 UPS icons and meanings Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 43-3...
The voltage output connector at the UPS is a 3.5 mm, removable, 7-pin screw terminal connector (ANSI: accepts 16 to 26 AWG). A 7-position Phoenix IDC connector is used at the ONT. 43-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
UPS Connector 1/4 in. (.64 cm) Black Green Slate Brown Blue Orange 18977 43.8 Specifications The following specifications apply to the UPS. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 43-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
0 to 50 000 ft above sea level (0 to 15 000 m) • relative humidity (non-condensing) within enclosure: 0% to 95% 43-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 419
5528 WAM 5528 Web-based Access Manager The Alcatel-Lucent 5528 Web-based Access Manager is a web server-based network manager software. The 5528 WAM allows registered users to connect to the NE through the Internet or craft port, providing a uniform and simplified method of monitoring, provisioning, and configuring NEs.
Page 420
An electronic device that controls the gain of a signal to ensure some level of performance over changing conditions. Access Identifier Alarm Indication Signal Alarm GL-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 421
Measure of transmission quality expressed as the percentage of received bits in error compared to the total number of bits received. BITS Building Integrated Timing Supply Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 422
ONT systems with regards to the use of hazardous substances in products and subassemblies. Channel Identifier or Consecutive Identical Digit CLEC Competitive Local Exchange Carrier CLEI Common Language Equipment Identifier GL-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 423
Glossary Command Line Interface A workstation access method interface that uses CLI commands to communicate to any network element in the 7342 ISAM FTTU network. Central Office Telephone switching center that connects subscribers within a telephone network. CODEC Coder Decoder...
Page 424
EDFA is used in transmitter booster amplifiers, in-line repeating amplifiers, and receiver preamplifiers. Equipment Engineering GL-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 425
Federal Communications Commission (U.S.) Frame Check Sequence Food and Drug Agency (U.S.) Forwarding Database Forward Error Correction FGND Frame Ground Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-7 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 426
High Speed Internet hazardous substance table The HST lists the hazardous substances present in products and subassemblies, as required by CRoHS legislation. GL-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 427
ISDN service: Basic Rate Interface (BRI) and Primary Rate Interface (PRI). Internet Service Provider A regional network-providing Internet service Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-9 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 428
The IEEE sublayer in a local area network that controls access to the shared medium by local area network attached devices. Media Attachment Unit Ethernet connector. Maximum Burst Size GL-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 429
Mean Time To Repair Network Address Translation Narrow Band Network Element Hardware or combined hardware-software that is designed to perform within a telecommunications system. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-11 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 430
Network-to-Node Interface Normal Network Service Provider Network Termination A card that provides a link to an Ethernet-based network. The 7342 ISAM FTTU uses the EHNT-A. Non-Trouble Procedure Network Time Protocol Network Timing Reference Operations, Administration, and Maintenance Broad categories of functions found in a communications network and/or the business processes found in network service provider companies.
Page 431
Optical Network Terminal Equipment that provides voice, data, and video services and terminates the 7342 ISAM FTTU network at a subscriber location. ONTs provide services to a single family home, a business location, or a multidwelling residence, such as an apartment complex or condominium. Services can include POTS, high-speed Ethernet, IPTV, and RF video.
Page 432
Ethernet network. P-OLT Packet Optical Line Termination The fully assembled shelf in the 7342 ISAM FTTU system. The P-OLT consists of two NT cards (for redundancy), one AACU card, and 18 LT cards. Passive Optical Network A fiber-based network that uses passive splitters to deliver signals to multiple users.
Page 433
Restricted Access Location Remote Access Multiplexer Remote Defect Indication Relay Detection Mechanism Random Early Detection Radio Frequency Routing Gateway Residential Gateway Relative Humidity Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-15 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 434
A physically compact connector design that has been developed for use in fiber optic systems. These connectors are about half the size of conventional connectors. GL-16 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 435
A method of synchronizing network nodes. An SNTP server can be used by multiple nodes to synchronize themselves. System-on-a-Chip SOHO Small Office Home Office Strict Priority Serial Peripheral Interface Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-17 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 436
TFTP Trivial File Transfer Protocol Telecommunications Industries Association The group responsible for setting telecommunications standards in the United States. GL-18 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 437
(NT) side, transmit (Tx) indicates the upstream direction of the transmission to the network. On the line termination (LT) side, receive (Rx) indicates the upstream direction of the transmission to the OLT. Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-19...
Page 438
VDSL consists of two versions: VDSL1, which is the original VDSL, and VDSL2. The 7342 ISAM FTTU supports VDSL2. VDSL1 is converted to VDSL2 on migration to release FGU 04.05.05 and higher.
Page 439
A general term that is used to refer to more than one type of unspecified DSL (for example, ADSL, ADSL2, READSL, SHDSL, VDSL2). 10-gigabit Ethernet (GE) small form-factor pluggable Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 GL-21 3FE 51892 AAAA TCZZA...
Page 440
Glossary GL-22 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 441
SoC based over Ethernet, 5-4 gratuitous ARP anti-spoofing, 4-10 SoC based over MoCA, 5-6 source address anti-spoofing, 4-10 with additional 10/100/100Base-T hardware, 5-9 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 IN-1 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 442
GPON transmission, 4-3 MoCA subsystem gratuitous ARP requests SoC based, 5-6 anti-spoofing, 4-10 Modular ONT TCA, 11-10 VDSL performance monitoring, 11-10 IN-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 443
24-2, 25-2, 26-2, 27-2, 28-2, 29-2, 30-4, ANSI safety labels, viii 31-4, 32-2 ANSI safety standards, ix electrostatic discharge, xi, xix environmental requirements, xiv, xxiii Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 IN-3 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 444
4-10 service unit ONTs Raman reduction, 6-17 LEDs, 9-18 RF video coaxial, 10-14 configuration recommendations, 10-16 Raman reduction, 6-17 IN-4 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 445
VDSL performance monitoring, 11-9, 11-10 visual indicators, 8-1, 9-1 voice subsystem SoC based, 5-4 voice subsystems with additional POTS hardware, 5-9 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 IN-5 3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual...
Page 446
Index IN-6 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA...
Page 447
Customer documentation http://www.alcatel-lucent.com/osds Product manuals and documentation updates are available through the Alcatel-Lucent Support Documentation and Software Download service at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative. Technical support http://www.alcatel-lucent.com/support...