NEC EXPRESS5800/140He Service Manual page 159

Hide thumbs Also See for EXPRESS5800/140He:
Table of Contents

Advertisement

[Errors on maintenance/replacement device information (FRU) display]
No.
Error message
1
The DRU is acquired
unsuccessfully.
[BMC configuration errors]
No.
Error message
1
The setting failed.
2
The BMC configuration is
acquired unsuccessfully.
3
The BMC is now used by
another software. Retry the
operation after a while.
4
The BMC configuration file is
illegal.
5
Required XML tags are not
found.
6
The file is saved
unsuccessfully.
7
The user name is too long.
8
The user name includes one
or more illegal characters.
9
The password is too long.
10
The password does not
match the registered one.
11
The HTTP port number is
illegal.
12
The SSL port number is
illegal.
13
The HTTP port number is the
same as the SSl port number.
14
The login trial period is illegal.
15
The possible login failure
count is illegal.
16
The account lock period is
illegal.
17
The IP address is illegal.
18
The subnet mask is illegal.
19
The default gateway is illegal.
20
The IP address of the DNS
server is illegal.
21
The host name is illegal.
Action
This may be caused by network congestion. Retry
the operation. If the operation fails several times,
replace the Management LAN Board. If the error still
occurs, the BMC may be defected. Replace the I/O
Board.
Action
After checking the network environment, retry the
operation. If the operation fails several times, replace
the Management LAN Card. If the error still occurs,
replace the I/O Board.
Retry the operation after a while.
The BMC configuration file may be broken. Check
the file.
The BMC configuration file is saved incorrectly. After
changing the storage destination, retry the operation.
The user name should be up to 32 characters.
The user name can only accept alphanumeric
characters, "-" (minus sign) and "_" (underscore).
The password should be up to 16 characters.
Reenter the password.
Numeric characters are only available.
The port numbers cannot be the same with each
other. Specify different port numbers.
Numeric characters are only available.
Specify the IP address with numeric characters and
periods.
The host name can only accept alphanumeric
characters, "-" (minus sign) and "_" (underscore). It
should be up to 256 characters.
-
-
143